Jiang Hsieh - Academia.edu (original) (raw)

Related Authors

Alexei Kouprianov

Rigas Arvanitis

Alberto Montaner

Isad Saric

Hanno Pahl

Hanno Pahl

Rheinische Friedrich-Wilhelms-Universität Bonn

Tiago Luís Gil

Maria Rentetzi

Adnan Awad

E.i.abdul Sathar

Sylvia Frazier-Bowers

Uploads

Papers by Jiang Hsieh

Research paper thumbnail of Methods and apparatus for image reconstruction

Research paper thumbnail of Comparison of reconstruction algorithms to extend CT reconstruction field-of-view

2007 IEEE Nuclear Science Symposium Conference Record, 2007

This paper evaluates the impact of reconstruction algorithms to extend CT reconstruction field-of... more This paper evaluates the impact of reconstruction algorithms to extend CT reconstruction field-of-view (DFOV) on radiation dose calculation for oncology treatment planning. Three recon algorithms for extending DFOV are compared: 1) a symmetric-mirroring (SM) algorithm; 2) a sinogram interpolation (SI) algorithm; and 3) a water-cylinder fitting (WF) algorithm. Each of the IQ and anthropomorphic phantoms is scanned twice using GE Lightspeed 16. The first scans, where the phantoms are positioned inside the 50 cm DFOV, are used to establish the "ground truth"; while in the 2nd scans, the phantoms are positioned in such way that the edges are 4-8 cm outside the 50 cm DFOV. For quantitative assessment, a point of interest within 50 cm DFOV is chosen for each phantom, to which the accumulative attenuation in all views is calculated as a lst-order approximation of dose to be delivered to the point. The performance of the algorithms is evaluated by accumulative attenuation accuracy by comparing with the "ground truth". In reconstruction from all three algorithms, objects outside 50 cm DFOV are restored but image quality and accumulative attenuation varies among algorithms. The SM reconstruction results in restoration of low-attenuating objects in small truncation cases, but its ability to restore high-attenuating objects in large truncation cases is limited and produces worst attenuation accuracy due to the overly simplicity of the algorithm. The SI algorithm provides improved accuracy even in large truncation cases, especially for large-attenuating objects. But the CT number still significantly depart from the ground truth due to the lack of consistency in sinogram interpolation. WF produces significantly better image quality and >17% higher accuracy than SM and SI in all cases. In summary, it is feasible to extend the CT DFOV with algorithmic corrections. Among the selected algorithms, the WF algorithm provides reconstructions with the best quality for oncology treatme- nt planning.

Research paper thumbnail of Conjugate cone-beam reconstruction algorithm

Optical Engineering, 2007

ABSTRACT

Research paper thumbnail of Methods and apparatus to facilitate reconstruction of images

Research paper thumbnail of METHODS AND APPARATUS FOR CT SMOOTHING TO REDUCE ARTIFACTS

Research paper thumbnail of Method and apparatus for reconstructing images of moving structures based on motion cycle temporal data

US Patent Sep. 18,2001 Sheet 1 of 5 US 6,292,530 Bl FIG, 1 PRIOR ART detector x-ray source , 2 de... more US Patent Sep. 18,2001 Sheet 1 of 5 US 6,292,530 Bl FIG, 1 PRIOR ART detector x-ray source , 2 detector x-ray source ... US Patent Sep. 18,2001 Sheet 2 of 5 US 6,292,530 Bl c c 18 \ C CONTROLLER 17 FIG. 3 15 DETECTOR CONTROLLER ^ y» RECONSTRUCTION ALGORITHM ...

Research paper thumbnail of Step-and-shoot cardiac CT imaging

Research paper thumbnail of Methods and systems to facilitate reducing banding artifacts in images

Research paper thumbnail of SYSTEM AND METHOD OF INCREASING TEMPORAL RESOLUTION OF AN X-RAY IMAGE

Research paper thumbnail of Apparatus and method for z-location dependent x-ray beam filtration for imaging system

Research paper thumbnail of Methods and apparatus for helical multi-frame image reconstruction in a computed tomography fluoro system including data communications over a network

Research paper thumbnail of A Study of Four Minimization Approaches forIterative Reconstruction in X-Ray CT

Research paper thumbnail of Methods and apparatus for cardiac imaging with conventional computed tomography

Research paper thumbnail of Methods and apparatus for compensating computed tomographic channel ganging artifacts

Research paper thumbnail of METHODS AND SYSTEMS FOR IMPROVING SPATIAL AND TEMPORAL RESOLUTION OF COMPUTED IMAGES OF MOVING OBJECTS

Research paper thumbnail of Image quality evaluation of a LightSpeed CT750 HD computed tomography system

Proceedings of Spie the International Society For Optical Engineering, Feb 1, 2009

With the advancement of Computed Tomography technology, improving image quality while reducing pa... more With the advancement of Computed Tomography technology, improving image quality while reducing patient dose has been a big technical challenge. The recent CT750 HD system from GE Healthcare provides significantly improved spatial resolution and the capability to reduce dose during routine clinical imaging. This paper evaluates the image quality of this system. Spatial resolution, dose reduction, noise, and low contrast detectability have been quantitatively characterized. Results show a quantifiable and visually discernable higher spatial resolution for both body and cardiac scanning modes without compromise of image noise. Further, equivalent image quality performance with up to 50% lower dose has been achieved.

Research paper thumbnail of Temporal Resolution Improvement Prior Image Constrained Compressed Sensing (TRI-PICCS): Performance as a Function of Achievable Temporal Resolution Improvement

Research paper thumbnail of Systems and methods for improving a resolution of an image

Research paper thumbnail of Methods and systems to facilitate reducing cone beam artifacts in images

Research paper thumbnail of Methods, apparatus, and software for reconstructing an image

Research paper thumbnail of Methods and apparatus for image reconstruction

Research paper thumbnail of Comparison of reconstruction algorithms to extend CT reconstruction field-of-view

2007 IEEE Nuclear Science Symposium Conference Record, 2007

This paper evaluates the impact of reconstruction algorithms to extend CT reconstruction field-of... more This paper evaluates the impact of reconstruction algorithms to extend CT reconstruction field-of-view (DFOV) on radiation dose calculation for oncology treatment planning. Three recon algorithms for extending DFOV are compared: 1) a symmetric-mirroring (SM) algorithm; 2) a sinogram interpolation (SI) algorithm; and 3) a water-cylinder fitting (WF) algorithm. Each of the IQ and anthropomorphic phantoms is scanned twice using GE Lightspeed 16. The first scans, where the phantoms are positioned inside the 50 cm DFOV, are used to establish the "ground truth"; while in the 2nd scans, the phantoms are positioned in such way that the edges are 4-8 cm outside the 50 cm DFOV. For quantitative assessment, a point of interest within 50 cm DFOV is chosen for each phantom, to which the accumulative attenuation in all views is calculated as a lst-order approximation of dose to be delivered to the point. The performance of the algorithms is evaluated by accumulative attenuation accuracy by comparing with the "ground truth". In reconstruction from all three algorithms, objects outside 50 cm DFOV are restored but image quality and accumulative attenuation varies among algorithms. The SM reconstruction results in restoration of low-attenuating objects in small truncation cases, but its ability to restore high-attenuating objects in large truncation cases is limited and produces worst attenuation accuracy due to the overly simplicity of the algorithm. The SI algorithm provides improved accuracy even in large truncation cases, especially for large-attenuating objects. But the CT number still significantly depart from the ground truth due to the lack of consistency in sinogram interpolation. WF produces significantly better image quality and >17% higher accuracy than SM and SI in all cases. In summary, it is feasible to extend the CT DFOV with algorithmic corrections. Among the selected algorithms, the WF algorithm provides reconstructions with the best quality for oncology treatme- nt planning.

Research paper thumbnail of Conjugate cone-beam reconstruction algorithm

Optical Engineering, 2007

ABSTRACT

Research paper thumbnail of Methods and apparatus to facilitate reconstruction of images

Research paper thumbnail of METHODS AND APPARATUS FOR CT SMOOTHING TO REDUCE ARTIFACTS

Research paper thumbnail of Method and apparatus for reconstructing images of moving structures based on motion cycle temporal data

US Patent Sep. 18,2001 Sheet 1 of 5 US 6,292,530 Bl FIG, 1 PRIOR ART detector x-ray source , 2 de... more US Patent Sep. 18,2001 Sheet 1 of 5 US 6,292,530 Bl FIG, 1 PRIOR ART detector x-ray source , 2 detector x-ray source ... US Patent Sep. 18,2001 Sheet 2 of 5 US 6,292,530 Bl c c 18 \ C CONTROLLER 17 FIG. 3 15 DETECTOR CONTROLLER ^ y» RECONSTRUCTION ALGORITHM ...

Research paper thumbnail of Step-and-shoot cardiac CT imaging

Research paper thumbnail of Methods and systems to facilitate reducing banding artifacts in images

Research paper thumbnail of SYSTEM AND METHOD OF INCREASING TEMPORAL RESOLUTION OF AN X-RAY IMAGE

Research paper thumbnail of Apparatus and method for z-location dependent x-ray beam filtration for imaging system

Research paper thumbnail of Methods and apparatus for helical multi-frame image reconstruction in a computed tomography fluoro system including data communications over a network

Research paper thumbnail of A Study of Four Minimization Approaches forIterative Reconstruction in X-Ray CT

Research paper thumbnail of Methods and apparatus for cardiac imaging with conventional computed tomography

Research paper thumbnail of Methods and apparatus for compensating computed tomographic channel ganging artifacts

Research paper thumbnail of METHODS AND SYSTEMS FOR IMPROVING SPATIAL AND TEMPORAL RESOLUTION OF COMPUTED IMAGES OF MOVING OBJECTS

Research paper thumbnail of Image quality evaluation of a LightSpeed CT750 HD computed tomography system

Proceedings of Spie the International Society For Optical Engineering, Feb 1, 2009

With the advancement of Computed Tomography technology, improving image quality while reducing pa... more With the advancement of Computed Tomography technology, improving image quality while reducing patient dose has been a big technical challenge. The recent CT750 HD system from GE Healthcare provides significantly improved spatial resolution and the capability to reduce dose during routine clinical imaging. This paper evaluates the image quality of this system. Spatial resolution, dose reduction, noise, and low contrast detectability have been quantitatively characterized. Results show a quantifiable and visually discernable higher spatial resolution for both body and cardiac scanning modes without compromise of image noise. Further, equivalent image quality performance with up to 50% lower dose has been achieved.

Research paper thumbnail of Temporal Resolution Improvement Prior Image Constrained Compressed Sensing (TRI-PICCS): Performance as a Function of Achievable Temporal Resolution Improvement

Research paper thumbnail of Systems and methods for improving a resolution of an image

Research paper thumbnail of Methods and systems to facilitate reducing cone beam artifacts in images

Research paper thumbnail of Methods, apparatus, and software for reconstructing an image

Log In