M Taheri - Academia.edu (original) (raw)

M Taheri

Related Authors

Aidy Ali

Aidy Ali

Universiti Pertahanan Nasional Malaysia

Armando Marques-Guedes

Peter Hobson

Gordon N Fleming

Mikail F Lumentut

Aashique Rezwan

Vibhav Saraswat

Gautam Anand

Gautam Anand

Indian Institute of Engineering Science and Technology, Shibpur

Marcelo Paredes

Jonathan D Maltz

Uploads

Papers by M Taheri

Research paper thumbnail of Development of a high efficiency personal/environmental radon dosimeter using polycarbonate detectors

Journal of Radiological Protection, 2006

Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the... more Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the assessment of radon exposure. These methods are often applied in radon dosimetry for long periods of time. In this research work, we have developed a highly efficient method of personal/environmental radon dosimetry that is based upon the detection of alpha particles from radon daughters, (218)Po and (214)Po, using a polycarbonate detector (PC). The radon daughters are collected on the filter surface by passing a fixed flow of air through it and the PC detector, placed at a specified distance from the filter, is simultaneously exposed to alpha particles. After exposure, the latent tracks on the detector are made to appear by means of an electrochemical etching process; these are proportional to the radon dose. The air flow rate and the detector-filter distance are the major factors that can affect the performance of the dosimeter. The results obtained in our experimental investigations have shown that a distance of 1.5 cm between the detector and the filter, an absorber layer of Al with a thickness of 12 microm and an air flow rate of 4 l min(-1) offer the best design parameters for a high efficiency radon dosimeter. Then, the designed dosimeter was calibrated against different values of radon exposures and the obtained sensitivity was found to be 2.1 (tracks cm(-2)) (kBq h m(-3))(-1). The most important advantages of this method are that it is reliable, fast and convenient when used for radon dose assessment. In this paper, the optimized parameters of the dosimeter structure and its calibration procedure are presented and discussed.

Research paper thumbnail of Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Research paper thumbnail of Occupational dose assessment and National Dose Registry System in Iran

Radiation Protection Dosimetry, 2010

This report presents status of external and internal dose assessment of workers and introducing t... more This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent H(p) (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed.

Research paper thumbnail of Characteristic studies for fast detection of a wide energy range of alpha particles in polycarbonate detectors

Radiation Measurements, 2005

Research paper thumbnail of Sensitivity Study of PADC Track Detector with External Radiators

Journal of Applied Sciences, 2010

Research paper thumbnail of An investigation on the response of PADC detectors to neutrons

Applied Radiation and Isotopes, 2011

The response of PADC was calculated by Monte Carlo simulation using MCNPX code. H, C and O recoil... more The response of PADC was calculated by Monte Carlo simulation using MCNPX code. H, C and O recoils as well as nuclear reactions have been taken into account. The calculated results show important contribution to detection efficiency of PADC due to H, C and O recoils. The irradiated detectors with 241 Am-Be source and 241 Am-Be softened with a spherical polyethylene moderator were electrochemically etched. The paper presents the results of the experimental and Monte Carlo simulations, which are in a good agreement.

Research paper thumbnail of Simulation of an orifice scrubber performance based on Eulerian/Lagrangian method

Journal of Hazardous Materials, 2003

Research paper thumbnail of In-Situ TEM Observation of Physical Degradation of AlGaN/GaN Devices under Applied Electric Field

Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, ... more Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, USA, July 29 – August 2, 2012.

Research paper thumbnail of Development of a high efficiency personal/environmental radon dosimeter using polycarbonate detectors

Journal of Radiological Protection, 2006

Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the... more Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the assessment of radon exposure. These methods are often applied in radon dosimetry for long periods of time. In this research work, we have developed a highly efficient method of personal/environmental radon dosimetry that is based upon the detection of alpha particles from radon daughters, (218)Po and (214)Po, using a polycarbonate detector (PC). The radon daughters are collected on the filter surface by passing a fixed flow of air through it and the PC detector, placed at a specified distance from the filter, is simultaneously exposed to alpha particles. After exposure, the latent tracks on the detector are made to appear by means of an electrochemical etching process; these are proportional to the radon dose. The air flow rate and the detector-filter distance are the major factors that can affect the performance of the dosimeter. The results obtained in our experimental investigations have shown that a distance of 1.5 cm between the detector and the filter, an absorber layer of Al with a thickness of 12 microm and an air flow rate of 4 l min(-1) offer the best design parameters for a high efficiency radon dosimeter. Then, the designed dosimeter was calibrated against different values of radon exposures and the obtained sensitivity was found to be 2.1 (tracks cm(-2)) (kBq h m(-3))(-1). The most important advantages of this method are that it is reliable, fast and convenient when used for radon dose assessment. In this paper, the optimized parameters of the dosimeter structure and its calibration procedure are presented and discussed.

Research paper thumbnail of Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Research paper thumbnail of Occupational dose assessment and National Dose Registry System in Iran

Radiation Protection Dosimetry, 2010

This report presents status of external and internal dose assessment of workers and introducing t... more This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent H(p) (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed.

Research paper thumbnail of Characteristic studies for fast detection of a wide energy range of alpha particles in polycarbonate detectors

Radiation Measurements, 2005

Research paper thumbnail of Sensitivity Study of PADC Track Detector with External Radiators

Journal of Applied Sciences, 2010

Research paper thumbnail of An investigation on the response of PADC detectors to neutrons

Applied Radiation and Isotopes, 2011

The response of PADC was calculated by Monte Carlo simulation using MCNPX code. H, C and O recoil... more The response of PADC was calculated by Monte Carlo simulation using MCNPX code. H, C and O recoils as well as nuclear reactions have been taken into account. The calculated results show important contribution to detection efficiency of PADC due to H, C and O recoils. The irradiated detectors with 241 Am-Be source and 241 Am-Be softened with a spherical polyethylene moderator were electrochemically etched. The paper presents the results of the experimental and Monte Carlo simulations, which are in a good agreement.

Research paper thumbnail of Simulation of an orifice scrubber performance based on Eulerian/Lagrangian method

Journal of Hazardous Materials, 2003

Research paper thumbnail of In-Situ TEM Observation of Physical Degradation of AlGaN/GaN Devices under Applied Electric Field

Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, ... more Extended abstract of a paper presented at Microscopy and Microanalysis 2012 in Phoenix, Arizona, USA, July 29 – August 2, 2012.

Log In