samraat sharma - Academia.edu (original) (raw)
Related Authors
Defence Services Medical Academy (DSMA), Yangon, Myanmar (Burma)
Uploads
Papers by samraat sharma
IEEE Transactions on Power Electronics, 2019
The mathematical modeling of open-switch faults in two-level machine-side converters and the faul... more The mathematical modeling of open-switch faults in two-level machine-side converters and the fault-tolerant current control of isotropic permanent-magnet synchronous generators are discussed in this paper. The proposed converter model is generic for any open-switch fault and independent of the operation mode of the electrical machine. The proposed fault-tolerant current control system gives improved control performance and reduced torque ripple under open-switch faults by modifying the antiwindup strategy, adapting the space-vector modulation scheme, and by injecting additional reference currents. The theoretical derivations of model and control are validated by comparative simulation and measurement results.
The Simulation model of DDPMSG 10KW grid Connected are developed using MATLAB 2013(a) and FAST Si... more The Simulation model of DDPMSG 10KW grid Connected are developed using MATLAB 2013(a) and FAST Simulator. In addition to it SVPWM technique has been applied for 10KW grid connected model. Space vector pulse width modulation has been used for obtaining the output voltage with less distortion. The result so obtained show that there is a degree of freedom of space vector placement in a switching cycle. The fully controlled converter has been used to provide separate control for active and reactive powers. The simulation results in MATLAB SIMULINK 2013a showing the model have good dynamic and static performance. KeywordsDirect drive permanent magnet synchronous generator, space vector pulse width modulation, fully controlled converters.
Re-evaluation of emergency control and protection schemes for distribution and transmission netwo... more Re-evaluation of emergency control and protection schemes for distribution and transmission networks are one of the main problems posed by wind turbines in power systems. Change of operational conditions and dynamic characteristics influence the requirements to control and protection parameters.
IEEE Transactions on Power Electronics, 2019
The mathematical modeling of open-switch faults in two-level machine-side converters and the faul... more The mathematical modeling of open-switch faults in two-level machine-side converters and the fault-tolerant current control of isotropic permanent-magnet synchronous generators are discussed in this paper. The proposed converter model is generic for any open-switch fault and independent of the operation mode of the electrical machine. The proposed fault-tolerant current control system gives improved control performance and reduced torque ripple under open-switch faults by modifying the antiwindup strategy, adapting the space-vector modulation scheme, and by injecting additional reference currents. The theoretical derivations of model and control are validated by comparative simulation and measurement results.
The Simulation model of DDPMSG 10KW grid Connected are developed using MATLAB 2013(a) and FAST Si... more The Simulation model of DDPMSG 10KW grid Connected are developed using MATLAB 2013(a) and FAST Simulator. In addition to it SVPWM technique has been applied for 10KW grid connected model. Space vector pulse width modulation has been used for obtaining the output voltage with less distortion. The result so obtained show that there is a degree of freedom of space vector placement in a switching cycle. The fully controlled converter has been used to provide separate control for active and reactive powers. The simulation results in MATLAB SIMULINK 2013a showing the model have good dynamic and static performance. KeywordsDirect drive permanent magnet synchronous generator, space vector pulse width modulation, fully controlled converters.
Re-evaluation of emergency control and protection schemes for distribution and transmission netwo... more Re-evaluation of emergency control and protection schemes for distribution and transmission networks are one of the main problems posed by wind turbines in power systems. Change of operational conditions and dynamic characteristics influence the requirements to control and protection parameters.