Relay Switch & Contactor FAQs
Q&A on clicking chattering relay switches in Air Conditioners, Heat Pumps, Water Pumps, & other controls
- POST a QUESTION or COMMENT about contactor switch or relay switch noises in mechanical systems used in buildings or building air conditioners, heat pumps, water pumps or other equipment
Control relay switch chattering noise diagnosis and repair Q&A.
This article series discusses control relay switch chattering or rapid, repeated clicking noises, their cause, meaning, and repair.
Relay switches are widely used to control equipment found in or on buildings including air conditioning system or heat pump compressor/condenser unit compressor motors, fans, and in an air handler the blower fan used in forced air heating and air conditioning systems.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Clicking or chattering electrical relay switch FAQs
These questions and answers about clicking or chattering electrical control relays were posted originally
at RELAY CONTROL SWITCHES - be sure to see the diagnosis and repair advice given there.
I just installed a new compressor on a heat pump. The compressor was working fine then it stopped and won't turn on. About every 30 seconds it tries to turn on for a sec then nothing for 30 secs then tries again.
On 2018-05-07 by (mod) - every 30 seconds it tries to turn on
Sounds like excessive head pressure, maybe a stuck TEV
I have a hot water boiler for radiators and the circulator pump only runs when the burner is on.
I want to be able to manually over-ride the contactor/relay with an external switch to have the ciruclator run continuously during very cold outside temps.
Can I simply add a typical single-pole light switch between the L1 L2 line in and the C1 C2 circulator control? If not, how else to do this?
@Paul,
I've got the same issue up here in northern Minnesota. What image of the control system are you referring to in regard to the L1 L2 line and C1 C2 control? -Mike
A chattering relay is most likely failed or failing; in an emergency a short term repair is, with power off, to try to clean the contacts but it's difficult. SOME techs can replace a relay; most replace the whole control.
This illustration https://inspectapedia.com/heat/Honeywell\_R8182D\_Internals.jpg shows the two relays in a typical aquastat, one for the burner and one for the circulator.
The L1 L2 are the power or LINE-IN terminals
The C1 C2 are the wires that control the circulator
Those are shown in the lower right of the illustration found at this article:
That image is discussed a tAQUASTAT CONTROLS
That article includes links to PDF files that describe the installation and use of the aquastat.
Bottom line: you probably need a new relay or a new control.
My water pump leaked for along time where the pressure gauge is and then my water pressure just stopped period no water at all. I'm getting power but no water, wires are everywhere relay switch isn't connecting to turn pump on ethier. HELP.
Watch out: FOR safety turn off electrical power to the pump, then ask your electrician to replace the wet switch. And of coirse, fix the leak.
That's doesn't sound normal to me. I would ask for an investigation in repair by the service technician
An air conditioner repair man replaced the relay switch for a 24 VAC coil in the heating unit. Now whenever the air turns on I hear a continuous non stop clicking sound from the part. Is this normal or does it need to be fixed?
Thanks.
Katherine, also see our discussion of clicking relays in the page bottom COMMENTS about clicking aquastats at AQUASTAT CONTROLS inspectapedia.com/heat/Aquastats.php
...
Continue reading at RELAY CONTROL SWITCHES - topic home, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
- CAR / TRUCK AC PRESSURE SWITCH
- CAPACITORS for HARD STARTING MOTORS
- FAN NOISES, HVAC as ticking and chattering may be traced to a fan problem.
- RELAY CONTROL SWITCHES
- CAUSES of CONTACTOR / RELAY CHATTER
- CONTACTOR REPAIR, CLEANING POINTS - temporary repair success
- AIR CONDITIONER / HEAT PUMP RELAY SWITCH CONTACTOR CHATTERING
- HEAT or ELECTRIC HEAT CONTACTOR SWITCH CHATTER
- WATER PUMP CONTROL SWITCH CHATTERING
- WHERE to BUY REPLACEMENT RELAYS
- A/C CONDENSER CHATTER / BUZZ REPAIR SUCCESS
- NOISES, HVAC SOUND RECORDINGS
- NOISES, HVAC SYSTEM DIAGNOSIS
- WATER PUMP PRESSURE CONTROL SWITCH
Suggested citation for this web page
RELAY CONTROL SWITCH FAQs at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
INDEX to RELATED ARTICLES: ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING NOISE DIAGNOSIS
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.
In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com
We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.