Thermal Resistance and Accumulation of Heat by the Wall Construction (original) (raw)
Related papers
Calculation of the Thermal Dynamic Performance of the Residential Buildings’ Walls
Quality Production Improvement-QPI, 2019
Calculation of the thermal dynamic properties of the multi-layer wall isolation of residential buildings is presented in this paper. Taking into account that the final objective is to create a building with the highest energy efficiency ratio, i.e. with the lowest energy consumption, both for heating and cooling, it is necessary to realize the good thermal characteristics of the multi-layer wall. To obtain the optimal solution for the wall's structure, various wall structures with different thicknesses of the individual layers, were analyzed. Based on results, presented in this paper, one can conclude that for walls with the same total thickness, but various thicknesses of the individual layers, that constitute the complete wall structure, the differences appear in the delay of the change of the walls outside temperature. In that way, by varying those individual layers' thicknesses, one can obtain the optimal solution for the wall structure with the highest savings of energy.
Analysis of Wall Materials According to Thermal Parameters
Theory and building practice, 2022
Based on the analysis of energy consumption and carbon dioxide emissions of the construction industry, it is stated that the reduction of energy consumption in Ukraine is achieved through termomodernization of the existing building stock and build new buildings, which meet energy efficiency requirements. Comparison of thermal parameters of different wall materials are given. It is shown that multilayer wall constructions must be used to ensure the necessary indicators of external walls of energy efficient buildings. The use of effective wall materials allows to ensure compliance with the given temperature difference to regulatory documents and reducing of heat transfer by transmission during the heating season, solar heat gains during cooling season.
Thermal Performance and Energy Efficiency of Different Types of Walls for Residential Building
International Journal of Sustainable Construction Engineering and Technology
Decrement factor and time lag play an essential role in determining the thermal performance of a building envelope. Building walls, which form a major part of a building, have great influences on the energy consumption and indoor environment of a room. The indoor temperature considerably increases as the outdoor temperature increases. This scenario leads to excessive reliance on the mechanical cooling system, thereby increasing energy consumption. Therefore, this study aims to investigate the thermal performance and energy efficiency of different wall types. A building with a built-up area of 387.85m2 with six different wall materials is modelled and inputted in Energy Plus simulation software as an Intermediate Data Format file. The maximum and minimum surface indoor and outdoor temperatures are then obtained to determine the thermal performance of the wall material in terms of time lag and decrement factor. The energy efficiency of the wall materials is investigated by obtaining t...
Thermal and Economic Study on Building External Walls for Improving Energy Efficiency
International Journal of Heat and Technology
Energy consumption is a worldwide concern and improving insulation is a way to save energy in buildings. In Algeria about 42.7% of the total energy is consumed by residential sector. This study investigates the thermal behaviour of external walls used in buildings located in a chosen Algerian city under real climatic conditions. The transient heat conduction through a composite wall made of 3 or 5 parallel layers of different materials and thicknesses was numerically resolved. The equations system resolution was carried out by the finite differences method according to the Crank-Nicolson scheme. The outdoor temperature and the solar heat flux were approximated using analytic expressions, and were used as boundary conditions in the developed FORTRAN program. Simulations were performed for materials used in actual building constructions in Batna city as well as for materials proposed to improve insulation and an approach to define the costs of studied cases was developed. The results show that the actual way of construction gives poor thermal insulation. We proposed several technical solutions for new constructions as well as for the existing buildings to improve energy efficiency at lower costs.
Thermal Performance Assessment of External Wall Construction for Energy-Efficient Buildings
European Journal of Sustainable Development Research
Building envelope such as external walls are still constructed from poor materials which results in higher heating and cooling loads thereby raising energy bills. Improving building energy efficiency with advanced technologies is being sought. In this context, a numerical study was conducted to solve the coupled heat transfers through a standard wall structure used in Libyan residential buildings. Different techniques were compared to reduce the thermal transmittance of the traditional wall structure for saving energy including the application of radiant shield, low-e coating, insulating filling and external insulation. The numerical results revealed that the thermal radiation inside the cavities of hollow block is important and accounts for 21% of total heat transfer, while conductive and convective heat transfer contributes by 65% and 14% from the total, respectively. The obtained thermal transmittance value of the common wall structure was considered as high as 2.33 W/m 2 •K due to lower resistance of wall elements. The adoption of 50 mm layer of expanded polystyrene insulation (EPS) to the exterior wall showed the best thermal performance with a reduction of thermal transmittance by 45%. On the other hand, filling the interior of cavities with EPS resulted in a 37% reduction of thermal transmittance compared to 20% of using 3 mm aluminum foil as a radiant barrier in the middle of the cavities. The last case was less effective with a reduction of almost 10% when a commercial coating of 0.4 surface emissivity was applied to the interior of cavities.
This paper presents the comprehensive investigation of the effect divided air space thickness within the wall on unsteady heat transfer characteristics such as thermal transmittance, thermal admittance, decrement factor and time lag of five building material walls for energy efficient building enclosure design. The five building material composite walls such as laterite stone, mud brick, cellular concrete, dense concrete and cinder concrete with total thirty configurations were studied. A computer simulation program was developed to compute unsteady heat transfer characteristics using the cyclic admittance procedure. From the results, it is observed that the decrement factor decreases with the increase in the divided air space thickness within the composite wall for all building materials. Dense concrete was observed to be the energy efficient from the lowest decrement factor point of view among five studied building materials. Dense concrete decrement factor decreases by 23.65% for 0.02 m air space thickness compared to the conventional composite wall without air space. It is also noticed that the time lag increases with the increase in the divided air space thickness within the composite wall for all building materials. Cellular concrete was observed to be the energy efficient from highest time lag perspective among five studied building materials. Cellular concrete time lag increases by 6.23% for 0.02 m air space thickness compared to the conventional composite wall without air space. The results of the study help in designing energy efficient building enclosures.
Influence of Structure and Wall Materials on Building Thermal Performance
KnE Social Sciences
The passive cooling technique is a strategy to improve building thermal performance which is cost-effective, eco-friendly and best suited for the local climate. The building material is one of the elements in passive cooling techniques. The research aims to investigate the influence of building materials on building thermal performance by field measurements on test houses. Hobo data loggers were used to collect indoor air temperature and relative humidity data. FLIR Infrared Camera was used to collect surface temperature data. The National Standard for Ventilation and Air Conditioning system (SNI 03-6572-2001) used as a reference for thermal performance value. The scope of the research is investigating the influence of the structure and wall materials on building thermal performance. The structure materials for the experiment were steel material and concrete material. The wall materials for this experiment were clay brick, light concrete brick (AAC), GRC-Rockwool panel and GRC-Styro...
Thermal Behaviour Studies on Building Walls based on Type and Composition of the Materials
IOP Conference Series: Materials Science and Engineering, 2019
Controlling the thermal behaviour of buildings is very important because it affects the energy use in the buildings and impacts the thermal environment of the area. Thermal behaviour of the building is determined by the type and composition of the building material. This paper shows the thermal behaviour of several types and composition of commonly used building wall materials, i.e. brick, aerated concrete, laminated wood with glass wool insulation, and gypsum with glass wool insulation. For the thermal behaviour measurements, we used wall models exposed to halogen lamps of 2000 watts for 4 hours heating and 4 hours for cooling with a measurement interval of 5-15 minutes. Data retrieval using 8 thermocouples mounted on the surface and inserted inside the wall. The observed thermal behaviour phenomena are the heat flow on the walls, the time delay, and the heat capacity. The results show different maps of the thermal behaviour on the walls and indicating the need for additional therm...
Thermal performance of outer and inner multi-layered walls in buildings
Buildings’ outer walls are as a rule multi-layered, i.e. consisting in a sequence of homogeneous layers of different materials, some of which endowed with essentially resistive thermal features (light and insulating layers), some others with essentially capacitive thermal features (heavy layers, provided with mechanical resistance). Under steady state conditions, the thermal behaviour of a multi-layered wall is defined by its thermal transmittance, whose value is independent of the layer sequence order. Under dynamic thermal conditions, the behaviour of an outer multi-layered wall is defined by these two parameters: periodic thermal transmittance and time shift; whose value are strongly dependent on the layer sequence order. This study focus on how far these parameters are dependent on the sequence order of the layers forming the outer walls with the aim to detect the "ideal summer time stratigraphies".