In-vitro comparison of 3 knotting techniques for lateral fabellotibial suture stabilization (original) (raw)

Cortical suspensory button fixation has superior biomechanical properties to knotless anchor suture in anterior cruciate ligament repair: a biomechanical study

Chanyaphan Virulsri

Scientific Reports

View PDFchevron_right

Biomechanical evaluation of the Nice knot

Lauren Beaupre

International Journal of Shoulder Surgery, 2016

View PDFchevron_right

Determination of isometric points for placement of a lateral suture in treatment of the cranial cruciate ligament deficient stifle

Brian Beale

Veterinary and Comparative Orthopaedics and Traumatology, 2010

View PDFchevron_right

Initial Loop and Knot Security of Arthroscopic Knots Using High-Strength Sutures

Jeffrey E Rosen

Arthroscopy: The Journal of Arthroscopic & Related Surgery, 2007

View PDFchevron_right

Loop and knot security of a novel arthroscopic sliding-locking knot using high-strength sutures

Stephen A Parada

Journal of Orthopaedics, 2018

View PDFchevron_right

Mechanical testing of different knot types using high-performance suture material

T Kostuj

Knee Surgery, Sports Traumatology, Arthroscopy, 2013

View PDFchevron_right

Effect of tibial insertion site for lateral suture stabilization on the kinematics of the cranial cruciate ligament deficient-stifle during early, middle and late stance

Karanvir Aulakh

Veterinary and Comparative Orthopaedics and Traumatology, 2013

View PDFchevron_right

The Biomechanical Properties of Human Craniofacial Sutures and Relevant Variables in Sutural Distraction Osteogenesis: A Critical Review

James Tsoi

View PDFchevron_right

In Vitro Biomechanical Evaluation and Comparison of FiberWire, FiberTape, OrthoFiber, and Nylon Leader Line for Potential Use During Extraarticular Stabilization Of Canine Cruciate Deficient Stifles

Talita Wajczyk

View PDFchevron_right

The improved cortical button shows better breaking strength of sutures compared with 10 original cortical button after cyclic loading

Toshiaki Takahashi

Journal of Experimental Orthopaedics

View PDFchevron_right

A Biomechanical Analysis of a Tensioned Suture Device in the Fixation of the Ligamentous Lisfranc Injury

Timothy Beals

Foot & Ankle International, 2011

View PDFchevron_right

Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications

Peter Macdonald

Knee Surgery, Sports Traumatology, Arthroscopy, 2004

View PDFchevron_right

Finite Element Modeling and Experimental Characterization of Knot Configuration Effect on the Mechanical Performance of Surgical Suture

Arz Qwam Alden

2018

View PDFchevron_right

Clinical comparison and short-term radiographic evaluation of Tight Rope and Lateral Suture procedures for dogs after cranial cruciate ligament rupture

Slavomir Hornak

Veterinarni Medicina, 2014

View PDFchevron_right

The Effect of Six Knotting Methods on the Biomechanical Properties of Three Large Diameter Absorbable Suture Materials

L'Hocine Yahia

Veterinary Surgery, 2010

View PDFchevron_right

Extra-articular stabilization of the cranial cruciate deficient stifle with anchor systems

Iman Shaheed

Tierärztliche Praxis. Ausgabe K, Kleintiere/Heimtiere, 2011

View PDFchevron_right

Three-dimensional kinematic evaluation of lateral suture stabilization in an in vitro canine cranial cruciate deficient stifle model

Bertrand Lussier

PLoS ONE, 2021

View PDFchevron_right

Knots Tied With High–Tensile Strength Tape Biomechanically Outperform Knots Tied With Round Suture

Ming-long Yeh

Orthopaedic Journal of Sports Medicine, 2021

View PDFchevron_right

The Surgical Knot Conundrum –

Kyrin Liong

2021

View PDFchevron_right

A Biomechanical and Ease of Learning Comparison Study of Arthroscopic Sliding Knots

Razif Ali

Indian Journal of Orthopaedics, 2020

View PDFchevron_right

Cyclic testing of arthroscopic knot security

Philip Noble

Arthroscopy: The Journal of Arthroscopic & Related Surgery, 2004

View PDFchevron_right

Modification of Side-locking Loop Suture Technique Using an Antislip Knot for Repair of Achilles Tendon Rupture

Yuji Uchio

The Journal of Foot and Ankle Surgery, 2013

View PDFchevron_right

Extra - articular stabilization of cranial cruciate ligament- dificient stifle in Dogs: A new Tibial suture Anchor point

marwa ali

Journal of Applied Research in Veterinary Medicine the, 2013

View PDFchevron_right

Changes in Knot-Holding Capacity of Sliding Knots In Vivo and Tissue Reaction

Sabri Altıntaş

Archives of Surgery, 1998

View PDFchevron_right

Nice Knot and Surgical Knot Security in Reverse Shoulder Arthroplasty with Different High Strength Suture Materials -An In Vitro Mechanical Study

Ashish Babhulkar

View PDFchevron_right

Assessment of Four Tissue Models on Knot Tensile Strength

Imran Iqbal

Journal of Surgical Education, 2012

View PDFchevron_right

The behaviour of knots and sutures during the first 12 hours following a Bankart repair

Cronan Kerin

2008

View PDFchevron_right

Sutures and knots resistance to traction: an in vitro study

Luca Francetti

2020

View PDFchevron_right

Biomechanical comparison of the primary stability of suturing Achilles tendon rupture: a cadaver study of Bunnell and Kessler techniques under cyclic loading conditions

Thore Zantop

Archives of Orthopaedic and Trauma Surgery, 2008

View PDFchevron_right

The clinical outcome of three procedures for extraarticular stabilization of cranial cruciate ligament injuries in dogs

Cristian Zaha

TURKISH JOURNAL OF VETERINARY AND ANIMAL SCIENCES, 2019

View PDFchevron_right

An evaluation of knot integrity when tied robotically and conventionally

Aaron Bonham

American Journal of …, 2009

View PDFchevron_right

Physical and Mechanical Evaluation of Five Suture Materials on Three Knot Configurations: An in Vitro Study

José Nart

Polymers, 2016

View PDFchevron_right

Anatomic Suture Anchor Versus the Brostrom Technique for Anterior Talofibular Ligament Repair: A Biomechanical Comparison

Robert F . LaPrade

The American Journal of Sports Medicine, 2012

View PDFchevron_right

In vitro 3-dimensional kinematic evaluation of 2 corrective operations for cranial cruciate ligament-deficient stifle

Bertrand Lussier

Canadian journal of veterinary research = Revue canadienne de recherche vétérinaire, 2007

View PDFchevron_right