Computational Analysis of Indoor Thermal Comfort in a Terraced Family House with Thermal Insulation (original) (raw)
Related papers
Hygrothermal Response of a Dwelling House. Thermal Comfort Criteria
The use of local natural materials in order to reduce the environmental negative impact of buildings has become common practice in recent years; such buildings are to be found in all regions of the planet. The high level of thermal protection provided by the envelope elements made from natural materials such as straw bale insulation, hemp insulation or sheep wool, and their lack of thermal massiveness require a more complex analysis on their ability to keep interior comfort without accentuated variations. This paper proposes a comparative analysis between different solutions for a residential building located near a Romanian city, Cluj-Napoca. The elements of the building envelope are designed in three alternative solutions, using as substitute to classical solutions (concrete and polystyrene, masonry and polystyrene), straw bales and rammed earth for enclosing elements. For this purpose there are conducted numerical simulations of heat and mass transfer, using a mathematical model ...
Simulation of Thermal Comfort of a Residential House
In hot and humid climates thermal comfort can become a problem to the occupants of many residential buildings especially when they are not equipped with air-conditioning system. This paper presents outcomes of an ongoing research work to investigate thermal comfort level in a naturally ventilated residential house in Malaysia using computational fluid dynamics (CFD) method. Actual measurements of the temperature distribution, relative humidity and air flow pattern were conducted. CFD simulations on the model of the house allow us to visualize the temperature distribution and air flow pattern and velocity in the house. The thermal comfort in the house was found to be well outside the limits specified by ASHRAE standards. CFD simulation was used to investigate the effects of using a ceiling fan installed in the middle of the hall section and rotating at 150 RPM. It was found that the fan produced swirling flow pattern in the hall section resulting in a more uniform temperature distribution inside the house. However, there is no significant improvement in the thermal comfort level in the house. Results of CFD simulations also show that the use of small extractor fans installed on the front and back walls has no significant effects on the thermal comfort level in the house. Although the mechanical ventilation devices did not help improve the thermal comfort in the house being studied, the CFD simulation results can be used by building designers and engineers to further improved the level of thermal comfort in residential houses in hot and humid climates that are naturally ventilated.
Abstract From the results of research studies on the impact of the use of insulation in buildings, reducing solar radiation on buildings to improve indoor comfort by applying the Principles of radiation reduction in buildings naturally using insulation application that serves as an insulator against the building materials, use of thermal insulation in particular mounted on the roof of the building and the walls are located on second floor and the third floor Lauser office building, Calculate the cooling load for each room that was on second floor and the third floor based on the geographical location or position of the building, climate data, building material data , and the intensity of the spatial characteristics which include lighting, solar radiation, user activity and electrical appliances being used. The calculation is done with the help of Ecotech v.5, 2011. The location and position on the third floor of a building with a flat roof cast concrete, so that the heat absorbed by the platform, and two times greater than the amount of heat radiation is absorbed by the material in the direction of the light falling the sun is at an angle <30°C. The simulation results on the building with the addition of thermal insulation on all walls and the roof of the inside of the foam material ultrafolmadehid, without changing the model building and similar activities in accordance with the existing condition and the condition of the room using the air conditioner at a temperature of 18-26°C, indicating a decrease in cooling load signifinikan in any space reaches 40% of the total cooling load required on the lauser office building. Comparing the simulation results Ecotech temperature v.5 2011 with field measurements as a validation of the simulation results in order to achieve thermal comfort in buildings and can menggurangi use energy consumption in buildings and can be used as a reference in planning space-based conditioning systems energy efficient. Keywords: thermal insulation, thermal comfort, office building, insulator, cooling load
The Effect of Temperature and Moisture Variation on the Heat Transfer Through Building Envelope
Proceedings of the 4th International Conference on Civil, Structural and Transportation Engineering (ICCSTE'19), 2019
This paper investigates the impact of the change of thermal conductivity of the insulation layer embedded in a typical residential building on the cooling effect. The simulation has been performed using the polystyrene (EPS), in extremely hot conditions of Al Ain (UAE) at different level of densities denoted as low density LD (12 kg/m3), high density HD (20 kg/m3), ultra-high density UHD (30 kg/m3) and super-high density SHD (35 kg/m3), and three moisture content levels (10%, 20%, and 30%) compared to dry insulation material for LD. The change of the thermal conductivity of the EPS material at different operating temperatures and moisture content has been investigated. The thermal wall resistance was evaluated by applying a conjugate heat transfer model based on enthalpy-based formulation. The thermal performance of the building incorporating polystyrene with variable thermal conductivity (λ-value) was compared to a constant thermal conductivity by quantifying the additional cooling demand and capacity due to the λ-relationship with time using the e-quest as a building energy analysis tool. The results show that, when the λ-value is modelled as a function of operating temperature, its effect on the temperature profile during daytime is significant compared with that obtained when a constant λ-value for the polystyrene (EPS) insulation is adopted, however, this trend is reversed at night time. A similar trend in the evolution of temperatures across the wall section was observed when EPS material was tested with different densities and moisture contents. The monthly energy consumption for cooling required by the building is found to be higher in case of variable thermal conductivity for LD sample. The yearly average change in space cooling demand and cooling capacity employing polystyrene with constant and variable thermal conductivity increases with the increase of the moisture content. Indeed, the highest change in cooling demand and capacity are 6.5% and 8.8% with 30% moisture content.
Malaysia and Singapore are located close to the equator and hence are subjected to a very harsh, hot and humid climate. The Solar radiation intensities are coupled with high relative humidity values. Due to the increased affluence of the population, air conditioning of buildings (both commercial and residential) has become one of the design necessities. It is thus imperative to determine the optimum design conditions for thermal comfort so that we can utilise the natural energies in achieving thermal comfort or to minimise air-conditioning usage as an energy conservation strategies. This paper reviews the thermal comfort requirements under the equatorial climate. These are based on actual measurements done in Malaysia and in Singapore on a fairly large population sample. Wetting of the external wall is proposed as a strategy to attain the desired room conditions, without resorting to air-conditioning. The wetting of the external wall acts effectively as a shading device as well as to increase the heat transfer rate at the external surface. Some of the test results are presented. The results would be applicable to buildings in an equatorial climate. Using the evaporative cooling for external walls can lead to considerable energy savings in buildings in an equatorial climate.
Journal of Islamic Architecture, 2014
From the results of research studies on the impact of the use of insulation in buildings, reducing solar radiation on buildings to improve indoor comfort by applying the Principles of radiation reduction in buildings naturally using insulation application that serves as an insulator against the building materials, use of thermal insulation in particular mounted on the roof of the building and the walls are located on second floor and the third floor Lauser office building, Calculate the cooling load for each room that was on second floor and the third floor based on the geographical location or position of the building, climate data, building material data , and the intensity of the spatial characteristics which include lighting, solar radiation, user activity and electrical appliances being used. The calculation is done with the help of Ecotech v.5, 2011. The location and position on the third floor of a building with a flat roof cast concrete, so that the heat absorbed by the platform, and two times greater than the amount of heat radiation is absorbed by the material in the direction of the light falling the sun is at an angle <30°C. The simulation results on the building with the addition of thermal insulation on all walls and the roof of the inside of the foam material ultrafolmadehid, without changing the model building and similar activities in accordance with the existing condition and the condition of the room using the air conditioner at a temperature of 18-26°C, indicating a decrease in cooling load signifinikan in any space reaches 40% of the total cooling load required on the lauser office building. Comparing the simulation results Ecotech temperature v.5 2011 with field measurements as a validation of the simulation results in order to achieve thermal comfort in buildings and can menggurangi use energy consumption in buildings and can be used as a reference in planning space-based conditioning systems energy efficient.
Thermal Performance and Energy Efficiency of Different Types of Walls for Residential Building
International Journal of Sustainable Construction Engineering and Technology
Decrement factor and time lag play an essential role in determining the thermal performance of a building envelope. Building walls, which form a major part of a building, have great influences on the energy consumption and indoor environment of a room. The indoor temperature considerably increases as the outdoor temperature increases. This scenario leads to excessive reliance on the mechanical cooling system, thereby increasing energy consumption. Therefore, this study aims to investigate the thermal performance and energy efficiency of different wall types. A building with a built-up area of 387.85m2 with six different wall materials is modelled and inputted in Energy Plus simulation software as an Intermediate Data Format file. The maximum and minimum surface indoor and outdoor temperatures are then obtained to determine the thermal performance of the wall material in terms of time lag and decrement factor. The energy efficiency of the wall materials is investigated by obtaining t...
Comparison between environmentally designed houses and standard houses regarding thermal behavior
IOP conference series, 2019
Based on the literature review and environmental studies, it is well known that the fundamental design standards focus on the building orientation, materials, form, window wall ratio, and passive tools for cooling in hot climates. This was the reason behind this paper, to verify and prove that if a building is designed according to these standards then it could achieve thermal comfort and energy efficiency. So, a comparison was held between four case studies, two of them were designed according to those standards and the other two were not. Hygrometer data loggers that measure ambient air temperature and relative humidity were placed in living rooms and on roofs in the four villas for one month in order to compare and analyse the measurements. In the coming paragraphs, each case study is explained and measurements and analysis are presented in order to reach the conclusion of this paper study. Fixed parameters were set for comparison between the four cases, those parameters were as follows: Orientation-wall thickness-building material-WWR (window wall ratio)-Number of Floors-Type of roof-Surroundings. Data was collected based on these parameters to be able to compare between the results. After comparing those parameters in the four villas, it was concluded the great influence of the surrounding buildings on each villa on its internal temperature. And so therefore a simulation has been made to measure the effect of the surrounding buildings.
The Effect of Using Insulation Techniques in External Walls of Buildings on Energy Consumption
In the last decades, as in most of the world countries, the interior environment of buildings became uncomfortable in the West Bank, which required an extensive use of heating and cooling that raises the running coasts of the buildings and the consumption of energy, and consequently negatively affect the environment. This study investigated the external wall systems and techniques of buildings in the West Bank and showed their different effect on the interior environment. Such a study provides a better understanding of the use of thermal insulation techniques, and how they could contribute in decreasing the need for heating and cooling and consequently lowering the running costs. A comparative study performed using a computer simulation experiment, to compute the monthly heating and cooling loads for a typical plan of a residential apartment with an area of 131.4 m², using TRANSYS program , where different system has been used for the exterior walls of this apartment every time. This experiment came out with a number of findings such as; the use of air gab as an insulation technique for different walls would decrease the total heating and cooling loads by 14-20%, and 42-56% when using insulation materials as an insulation technique. It can be concluded that using insulation techniques in external walls improves comfort satisfaction in side buildings, and minimize coast of functioning interior spaces. The use of thermal insulation for building envelope especially external walls is highly recommended to maintain and control the interior environment of buildings, lowering the use of energy for heating and cooling and protect the environment.