SPECT/multislice low-dose CT: a clinically relevant constituent in the imaging algorithm of nononcologic patients referred for bone scintigraphy (original ) (raw )Assessment of the impact of application of single-photon emission computed tomography and SPECT-CT on lesion categorisation in bone scintigraphy
Anita Brink
South African Journal of Radiology, 2016
View PDFchevron_right
Radionuclide bone scan SPECT-CT: lowering the dose of CT significantly reduces radiation dose without impacting CT image quality
Scott Trethewey
American journal of nuclear medicine and molecular imaging, 2017
View PDFchevron_right
Bone: From planar imaging to SPECT & PET/CT
Jasna Mihailovic
Archive of Oncology, 2012
View PDFchevron_right
A prospective study comparing 99m Tc-HDP planar bone scintigraphy and whole-body SPECT/CT with 18 F-fluoride PET/CT and 18 F-fluoride PET/MRI for diagnosing bone metastases
Jann Mortensen
Journal of Nuclear Medicine
View PDFchevron_right
Bone scintigraphy and the added value of SPECT (single photon emission tomography) in detecting skeletal lesions
Lorenzo Maffioli
The quarterly journal of nuclear medicine : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), 2001
View PDFchevron_right
Quantitative vs. Qualitative SPECT-CT Diagnostic Accuracy in Bone Lesion Evaluation—A Review of the Literature
Cristina Petroiu
Diagnostics, 2023
View PDFchevron_right
SPECT-CT for characterization of extraosseous uptake of 99mTc-methylene diphosphonate on bone scintigraphy
Sellam Karunanithi
Diagnostic and Interventional Radiology, 2013
View PDFchevron_right
Three-minute SPECT/CT is sufficient for the assessment of bone metastasis as add-on to planar bone scintigraphy: prospective head-to-head comparison to 11-min SPECT/CT
Henrik Bertelsen
EJNMMI research, 2017
View PDFchevron_right
OPTIMAL UTILIZATION OF GAMMA CAMERA TIME IN Tc-99m MDP BONE SCINTIGRAPHY
Zabah Jawa
2007
View PDFchevron_right
A new SPECT/CT reconstruction algorithm: reliability and accuracy in clinical routine for non-oncologic bone diseases
Zarrin Alavi
EJNMMI research, 2018
View PDFchevron_right
The Role of SPECT-Guided CT for Evaluating Foci of Increased Bone Metabolism Classified as Indeterminate on SPECT in Cancer Patients
Hafizur Rahman
Faridpur Medical College Journal, 2013
View PDFchevron_right
Bone scintigraphy: procedure guidelines for tumour imaging
Lorenzo Maffioli
European Journal of Nuclear Medicine and Molecular Imaging, 2003
View PDFchevron_right
Hybrid spect-CT for characterization of isolated vertebral lesions seen on bone scintigraphy: comparison with planar scintigraphy, spect and CT
Varun Dhull
Diagnostic and Interventional Radiology, 2012
View PDFchevron_right
Differentiation of Malignant and Degenerative Benign Bone Disease Using Tc99m MDP and Tc99m Citrate Scintigraphy
Anupam Mondal
Clinical Nuclear Medicine, 1998
View PDFchevron_right
Should SPECT-CT replace SPECT for the evaluation of equivocal bone scan lesions in patients with underlying malignancies?
Xolani Ndlovu
Nuclear Medicine Communications, 2010
View PDFchevron_right
Calcification as a cause of potential false-positive findings in bone scintigraphy verified with [68Ga]Ga-PSMA-11 PET/CT - a case report
Tadeusz Budlewski
Polish archives of internal medicine, 2021
View PDFchevron_right
Factors affecting standardized uptake value of 99mTc-MDP bone SPECT/CT: A phantom study
Kanyalak Wiyaporn
Journal of Physics: Conference Series, 2019
View PDFchevron_right
Society of Nuclear Medicine Procedure Guideline for Bone Scintigraphy version 3 . 0 , approved June 20 , 2003
Robert Henkin
2003
View PDFchevron_right
99mTc-MDP bone scintigraphy of the hand: comparing the use of novel cadmium zinc telluride (CZT) and routine NaI(Tl) detectors
Einat Even-sapir
EJNMMI Research, 2015
View PDFchevron_right
Radiation Dose Reduction Strategy for SPECT/CT Bone Scan
Yusra Zabarmawi
View PDFchevron_right
Comparison of single photon emission computed tomography-computed tomography, computed tomography, single photon emission computed tomography and planar scintigraphy for characterization of isolated skull lesions seen on bone scintigraphy in cancer patients
rakesh kumar
Indian journal of nuclear medicine : IJNM : the official journal of the Society of Nuclear Medicine, India, 2014
View PDFchevron_right
Prospective evaluation of planar bone scintigraphy, SPECT, SPECT/CT, 18 F-NaF PET/CT and whole body 1.5T MRI, including DWI, for the detection of bone metastases in high risk breast and prostate cancer patients: SKELETA clinical trial
Hannu Aronen
Acta Oncologica, 2015
View PDFchevron_right
Discerning the Role and Appropriate Timing of Furosemide Administration in 99mTc methylene diphosphonate Bone Scintigraphy: A randomized controlled trial
Praveen Gururani
2024
View PDFchevron_right
SPECT-CT in routine clinical practice
Shekhar Sharma
Nuclear Medicine Communications, 2012
View PDFchevron_right
18F-NaF PET/CT imaging versus 99mTc-MDP scintigraphy in assessing metastatic bone disease in patients with prostate cancer
Apostolos Karantanas
2019
View PDFchevron_right
Comparison of 18F-NaF Imaging, 99mTc-MDP Scintigraphy, and 18F-FDG for Detecting Bone Metastases
Habibollah Dadgar
World Journal of Nuclear Medicine
View PDFchevron_right
Diagnostic Performance of SPECT/CT Versus Diffusion-Weighted Mri in Characterization of Indeterminate Osseous Lesions Detected on Bone Scan
Ahmed Kandeel
2021
View PDFchevron_right
Comparison of the diagnostic accuracy of 99 m-Tc-MDP bone scintigraphy and 18 F-FDG PET/CT for the detection of skeletal metastases
Atul Taneja , Ambrose Huang
Acta radiologica (Stockholm, Sweden : 1987), 2014
View PDFchevron_right
Young Population Attending for Whole Body Technetium 99MDP Bone Scintigraphy: A Single Institution Experience
Hosam Halim
Journal of Bone Biology and Osteoporosis, 2018
View PDFchevron_right
Radionuclide Bone Scintigraphy: An Interesting Case Report
Sanowar Hossain
Bangladesh Journal of Nuclear Medicine, 2015
View PDFchevron_right