VALIDATION OF NUMERICAL APPROACHES FOR ELECTROMAGNETIC CHARACTERIZATION OF MAGNETIC RESONANCE RADIOFREQUENCY COILS (original) (raw)

Quantitative analysis of magnetic resonance radio-frequency coils based on method of moments

Fa-hsuan Lin

IEEE Transactions on Magnetics, 1999

View PDFchevron_right

Electromagnetic characterisation of MR RF coils using the transmission-line modelling method

Stuart Grieve

Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine, 2002

View PDFchevron_right

Numerical methods and software tools for simulation, design, and resonant mode analysis of radio frequency birdcage coils used in MRI: SIMULATION, DESIGN, & RESONANT MODE ANALYSIS OF RF COILS

ziya ider

Concepts in Magnetic Resonance Part B Magnetic Resonance Engineering

View PDFchevron_right

Numerical methods and software tools for simulation, design, and resonant mode analysis of radio frequency birdcage coils used in MRI

ziya ider

Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 2015

View PDFchevron_right

Electromagnetic method for sample-induced resistance calculation of magnetic resonance coils

Raj Mittra

International Journal of Biomedical Engineering and Technology, 2010

View PDFchevron_right

Assessment of a PML Boundary Condition for Simulating an MRI Radio Frequency Coil

Alayar Kangarlu

International Journal of …, 2008

View PDFchevron_right

Correction to "Quantitative analysis of magnetic resonance radio-frequency coils based on method of moment

Fa-Hsuan Lin

IEEE Transactions on Magnetics, 2000

View PDFchevron_right

Assessing the Electromagnetic Fields Generated By a Radiofrequency MRI Body Coil at 64 MHz: Defeaturing Versus Accuracy

Micaela Liberti

IEEE Transactions on Biomedical Engineering, 2016

View PDFchevron_right

Electromagnetic characterization of an MR volume coil with multilayered cylindrical load using a 2-D analytical approach

Riccardo Stara, Mirco Cosottini, James Tropp

Journal of Magnetic Resonance, 2013

View PDFchevron_right

A time-harmonic inverse methodology for the design of RF coils in MRI

Stuart Crozier

IEEE Transactions on Biomedical Engineering, 2002

View PDFchevron_right

Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla

Tamer Ibrahim

Magnetic Resonance in Medicine, 2005

View PDFchevron_right

A Practical Guide to Estimating Coil Inductance for Magnetic Resonance Applications

Angelo Galante

Electronics

View PDFchevron_right

Electromagnetic Field and Radio Frequency Circuit Co-Simulation for Magnetic Resonance Imaging Dual-Tuned Radio Frequency Coils

yan dou

IEEE transactions on magnetics, 2018

View PDFchevron_right

Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations

Alayar Kangarlu

… , IEEE Transactions on, 2005

View PDFchevron_right

Measurements of the radiofrequency field in magnetic resonance coils

latifa Bouchet

Measurement Science and Technology, 1998

View PDFchevron_right

Development and Optimization of Surface and Volume Radiofrequency Coils Suitable for Fast-Field-Cycling Magnetic Resonance Imaging (FFC-MRI)

chuka ugwu

Journal of Radiography and Radiation Sciences

View PDFchevron_right

Coil performance evaluation based on electrodynamics: tools for hardware design and validation in magnetic resonance imaging

Riccardo Lattanzi

2008

View PDFchevron_right

3D RF Coil Design Considerations for MRI

Journal of Electrical and Computer Engineering Innovations

2017

View PDFchevron_right

A theoretical and experimental study on transverse field radio frequency surface coils

Antonello Sotgiu

2010

View PDFchevron_right

Application of engineering analysis techniques to the design of magnetic resonance imaging (MRI) coils

Henry Power

Journal of Physics: Conference Series, 2008

View PDFchevron_right

An inverse design of an open, head/neck RF coil for MRI

Stuart Crozier

IEEE Transactions on Biomedical Engineering, 2002

View PDFchevron_right

Numerical evaluation of an 8-element phased array torso coil for magnetic resonance imaging

Nicholas Shuley

The Eighth Australian …, 2011

View PDFchevron_right

High-Field Magnetic Resonance Imaging With Reduced Field/Tissue RF Artefacts—A Modeling Study Using Hybrid MoM/FEM and FDTD Technique

Stuart Crozier

IEEE Transactions on Electromagnetic Compatibility, 2000

View PDFchevron_right

Biot–Savart-Based Design and Workbench Validation at 100 MHz of Transverse Field Surface RF Coils

Angelo Galante

Electronics

View PDFchevron_right

An inverse method for radio frequency phased array coil design in magnetic resonance imaging equipment

Stuart Crozier

Anziam Journal, 2007

View PDFchevron_right

Design of a Multi-Array Radio-Frequency Coil for Interventional MRI of the Female Breast

Peter Serano

View PDFchevron_right

Sodium Radiofrequency Coils for Magnetic Resonance: From Design to Applications

Francesca Frijia

Electronics, 2021

View PDFchevron_right

Optimization of saddle coils for magnetic resonance imaging

Carlos Salmón

Brazilian Journal of Physics, 2006

View PDFchevron_right

High-field magnetic resonance imaging using solenoid radiofrequency coils

Donald Maillet

Magnetic Resonance Imaging, 2012

View PDFchevron_right