Measurement of breath amplitudes: Comparison of three noninvasive respiratory monitors to integrated pneumotachograph (original) (raw)

Validation of respiratory inductive plethysmography using the Qualitative Diagnostic Calibration method in anaesthetized infants

J. Stocks

European Respiratory Journal, 1998

View PDFchevron_right

Pulmonary mechanics measurements by respiratory inductive plethysmography and esophageal manometry: Methodology for infants on non-invasive respiratory support

MARLA R. WOLFSON

Journal of neonatal-perinatal medicine, 2019

View PDFchevron_right

Measurement of tidal breathing flows in infants using impedance pneumography

Jari Viik

The European respiratory journal, 2017

View PDFchevron_right

Assessment of tidal volume over time in preterm infants using respiratory inductance plethysmography

Juliann Di Fiore

Pediatric Pulmonology, 1997

View PDFchevron_right

Quantitative estimation of ventilation in newborn infants using the impedance pneumogram

Theodore Li

Journal of Perinatal Medicine, 1977

View PDFchevron_right

Respiratory Oscillometry in Newborn Infants: Conventional and Intra-Breath Approaches

Zita Gyurkovits

Frontiers in Pediatrics, 2022

View PDFchevron_right

Measurements of respiratory mechanics in the newborn: A simple approach

Jacopo Mortola

Pediatric Pulmonology, 1987

View PDFchevron_right

Detection of Apneas in Infants During Sleep: A Study Comparing Thoracic Impedance and Inductive Plethysmography

Thomas Erler

2001

View PDFchevron_right

Automated respiratory inductive plethysmography to evaluate breathing in infants at risk for postoperative apnea

Ahmed Aoude

Canadian Journal of Anaesthesia-journal Canadien D Anesthesie, 2008

View PDFchevron_right

Tidal breathing flow measurement in awake young children by using impedance pneumography

Anna Pelkonen

Journal of Applied Physiology, 2013

View PDFchevron_right

Comparison of supine and prone noninvasive measurements of breathing patterns in fullterm newborns

Marvin Sackner

Pediatric Pulmonology, 1994

View PDFchevron_right

Assessment of pulmonary dynamics in normal newborns: a pneumotachographic method

Franco Simini

Journal of Perinatal Medicine, 1988

View PDFchevron_right

Occlusion maneuver to detect the relative contribution of the rib cage and abdomen to tidal volume using respiratory inductive plethysmography in infants

Luigi Gagliardi

Pediatric Pulmonology, 1996

View PDFchevron_right

Referencing lung volume for measurements of respiratory system compliance in infants

Jacopo Mortola

Pediatric Pulmonology, 1993

View PDFchevron_right

Tidal breath eNO measurements in a cohort of unsedated hospitalized neonates-A method validation

Pauline Reim

Pediatric Pulmonology, 2018

View PDFchevron_right

Tidal volume measurements in infants: Opto-electronic plethysmography versus pneumotachograph

CYDA MARIA ALBUQUERQUE REINAUX

Pediatric pulmonology, 2016

View PDFchevron_right

Respiratory compliance in infants—a preliminary evaluation of the multiple interrupter technique

Janet Stocks

Pediatric Pulmonology, 1992

View PDFchevron_right

Respiratory function measurements in infants: symbols, abbreviations and units

P. Quanjer

The European respiratory journal, 1995

View PDFchevron_right

Tidal breathing flow-volume curves with impedance pneumography during expiratory loading

Jari Viik

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference, 2013

View PDFchevron_right

A non-invasive technique for evaluation of respiratory efforts in preterm infants during feeding

sabrina lopes

Journal of Neonatal Nursing, 2013

View PDFchevron_right

Assessment of signal processing methods for measuring the respiratory rate in the neonatal intensive care unit

Lionel Tarassenko

IEEE Journal of Biomedical and Health Informatics

View PDFchevron_right

Validation of a non-invasive pressure–time index of the inspiratory muscles in spontaneously breathing newborn infants

Theodore Dassios

Journal of Clinical Monitoring and Computing

View PDFchevron_right

A Plethysmographic Method for Assessment of Lung Function in Mechanically Ventilated Very Low Birth Weight Infants

Ants Silberberg

Pediatric Research, 1991

View PDFchevron_right

Neonatal Respiratory Monitoring System Based on the Thoracic Expansion Measurement

Fabiola Araujo

2012

View PDFchevron_right

Measurement of Total and Compartmental Lung Volume Changes in Newborns by Optoelectronic Plethysmography

Antonio Pedotti

Pediatric Research, 2010

View PDFchevron_right

[Diagnosis of respiratory sleep disorders in newborns with suspected apneas: comparison between nocturnal saturometry and polygraphy]

Valentina Diaz

Revista chilena de pediatria, 2017

View PDFchevron_right

Intrasubject variability of repeated pulmonary function measurements in preterm ventilated infants

Mario Rojas

Pediatric Pulmonology, 1996

View PDFchevron_right

Toward better home respiratory monitoring: A comparison of impedance and inductance pneumography

Katsuyuki Miyasaka

Pediatrics International, 1994

View PDFchevron_right

Sources of methodological variability in phase angles from respiratory inductance plethysmography in preterm infants

James Kemp

Annals of the American Thoracic Society, 2014

View PDFchevron_right