Implantable Cardioverter Defibrillator Implanted by Nonthoracotomy Approach: Initial Clinical Experience with the Redesigned Transvenous Lead System (original) (raw)

Management of complications associated with a first-generation endocardial defibrillation lead system for implantable cardioverter-defibrillators

AM Mauro

The American Journal of Cardiology, 1990

View PDFchevron_right

Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with nonthoracotomy lead systems

Brian Williamson

Circulation, 1994

View PDFchevron_right

Compatibility of a nonthoracotomy lead system with a biphasic implantable cardioverter-defibrillator

James Porterfield, Richard Luceri

The American Journal of Cardiology, 1996

View PDFchevron_right

Nonthoracotomy lead system for implantable defibrillator

john kall

The Journal of Thoracic and Cardiovascular Surgery, 1993

View PDFchevron_right

Failure of an implantable cardioverter-defibrillator to redetect ventricular fibrillation in patients with a nonthoracotomy lead system

Nam Tran

Circulation, 1992

View PDFchevron_right

Factors associated with successful implantation of nonthoracotomy defibrillation lead systems

David Callans

American Heart Journal, 1996

View PDFchevron_right

Nonthoracotomy defibrillator implantation: A single-center experience with 200 patients

Hans Scheld

The Annals of Thoracic Surgery, 1994

View PDFchevron_right

Risk of failure of transvenous implantable cardioverter-defibrillator leads

Enno van der Velde

Circulation. Arrhythmia and electrophysiology, 2009

View PDFchevron_right

Experience of cardioverter-defibrillators inserted without thoracotomy: evaluation of transvenously inserted intracardiac leads alone or with a subcutaneous axillary patch

Luc Jordaens

Heart, 1993

View PDFchevron_right

Total Pectoral Implantation: A New Technique for Implantation of Transvenous Defibrillator Lead Systems and Implantable Cardioverter Defibrillator

Anthony Gomes

Pacing and Clinical Electrophysiology, 1993

View PDFchevron_right

Clinical Results with Electrophysiologist‐Implanted Cardioverter‐Defibrillators

Vaughn Payne

Pacing and Clinical Electrophysiology, 1997

View PDFchevron_right

Late Complications in Patients with Pectoral Defibrillator Implants with Transvenous Defibrillator Lead Systems: High Incidence of Insulation Breakdown

Anthony Gomes

Pacing and Clinical Electrophysiology, 1998

View PDFchevron_right

Acute Efficacy and Chronic Follow-Up of Patients with Non-Thoracotomy Third Generation Implantahle Defibrillators

Thomas Hilbel, Laurence Sterns

Pacing and Clinical Electrophysiology, 1994

View PDFchevron_right

Lead and device-related complications in the Antiarrhythmics Versus Implantable Defibrillators Trial

Michael Gold

American Heart Journal, 2001

View PDFchevron_right

Subcutaneous Implantable Cardiac Defibrillators: Indications and Limitations

Maria Bongiorni

Current Heart Failure Reports, 2014

View PDFchevron_right

Risk of Failure of Transvenous Implantable Cardioverter-Defibrillator LeadsCLINICAL PERSPECTIVE

Enno van der Velde

Circulation: …, 2009

View PDFchevron_right

Preliminary Experience with Nonthoracotomy Implantahle Cardioverter Defihrillators in Young Patients

Jack Kron

Pacing and Clinical Electrophysiology, 1994

View PDFchevron_right

Increased incidence of subacute lead perforation noted with one implantable cardioverter-defibrillator

David Milan

2007

View PDFchevron_right

Generator and lead-related complications of implantable cardioverter defibrillators

Akbar Shafiee

International cardiovascular research journal, 2014

View PDFchevron_right

Long-Term Follow-up of Transvenous Defibrillation Leads

Wataru Shimizu

Circulation Journal, 2006

View PDFchevron_right

Preliminary experience with a hybrid nonthoracotomy defibrillating system that includes a biphasic device: Comparison with a standard monophasic device using the same lead system

masood akhtar

Journal of The American College of Cardiology, 1994

View PDFchevron_right

Implantable Cardioverter Defibrillators in the United States: Understanding the Benefits and Limitations of Implantable Cardioverter Defibrillator Therapy Based on Clinical Trial Results

David Callans

Pacing and Clinical Electrophysiology, 1998

View PDFchevron_right

Shock efficacy of subcutaneous implantable cardioverter-defibrillator for prevention of sudden cardiac death: initial multicenter experience

Ali Aydin

2012

View PDFchevron_right

Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator

Michael Husby

Circulation, 2013

View PDFchevron_right

Reduction of defibrillation threshold and safety of usage of a new model of subcutaneous defibrillation lead

Jacek Kubica

Folia Medica Copernicana, 2014

View PDFchevron_right

The Azygos Defibrillator Lead for Elevated Defibrillation Thresholds: Implant Technique, Lead Stability, and Patient Series

Mitchell Faddis

Pacing and Clinical Electrophysiology, 2008

View PDFchevron_right

Should Unipolar Pacemaker Leads be Banned? Lessons from Pacemaker/Implantable Cardioverter Defibrillator Interactions

Richard Luceri

Pacing and Clinical Electrophysiology, 1997

View PDFchevron_right

An alternative technique of implanting a nontransvenous implantable cardioverter-defibrillator system in adults with no or limited venous access to the heart

Marcin Kowalski

Heart Rhythm, 2010

View PDFchevron_right