Characterization of a scintillating GEM detector with low energy x-rays (original) (raw)

First Results of a Scintillating GEM Detector for 2-D Dosimetry in an Alpha Beam

Jeffrey Hendrikse

IEEE Transactions on Nuclear Science, 2007

View PDFchevron_right

2D dosimetry in a proton beam with a scintillating GEM detector

Jacobus Schippers

Physics in medicine and biology, 2009

View PDFchevron_right

Effective atomic numbers, electron densities, and tissue equivalence of some gases and mixtures for dosimetry of radiation detectors

Prakhar Singh

Nuclear Technology & Radiation Protection, 2012

View PDFchevron_right

A scintillating GEM for 2D-dosimetry in radiation therapy

Jacobus Schippers

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002

View PDFchevron_right

Energy non-linearity effects in argon gaseous detectors in the region of the Ar K-absorption edge: experimental results

C. M . B . Monteiro

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003

View PDFchevron_right

The scintillation of CF$_{4}$ and its relevance to detection science

Rachel Chechik, Jerry Vavra

1994

View PDFchevron_right

RADIATION DOSIMETRY WITH A TRIPLE-GEM DETECTOR DOSIMETRÍA DE RADIACIONES CON UN DETECTOR TRIPLE-GEM

Hector Castro, Andrea Velasquez Moros

Momento, 2023

View PDFchevron_right

A scintillating gas detector for 2D dose measurements in clinical carbon beams

Jacobus Schippers

Physics in Medicine and Biology, 2008

View PDFchevron_right

Measurement of GEM Parameters With X-Rays

Davide Pinci

IEEE Transactions on Nuclear Science, 2003

View PDFchevron_right

Direct measurement of the electron density in electron-beam-irradiated Ar-<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline">mml:mrowmml:msubmml:mrow<mml:mi mathvariant="normal">Fmml:mrowmml:mn2</mml:ma...

Mordechai Lando

Physical review, 1987

View PDFchevron_right

Effective gain and Ion Back Flow study of triple and quadruple gem detector

Sourav Tarafdar

Cornell University - arXiv, 2020

View PDFchevron_right

Detectors Based on Ionisation in Gases

Stefaan TAVERNIER

Experimental Techniques in Nuclear and Particle Physics, 2009

View PDFchevron_right

Determination of argon and xenon absolute electroluminescence yields in Gas Proportional Scintillation Counters

Cristina M B Monteiro

2011

View PDFchevron_right

Spectral discrimination of Čerenkov radiation in scintillating dosimeters

M. Labalme

Medical Physics, 2005

View PDFchevron_right

Glow Curve Analysis Applied to the Discrimination of X Ray Versus Proton Irradiation

Noel Guardala

Radiation Protection Dosimetry, 2002

View PDFchevron_right

Construction of a Gas Electron Multiplier (GEM) Detector for Medical Imaging

Nagendra Mondal

arXiv (Cornell University), 2013

View PDFchevron_right

An argon gas proportional scintillation counter with UV avalanche photodiode scintillation readout

Cristina M B Monteiro

IEEE Transactions on Nuclear Science, 2001

View PDFchevron_right

Processing of amplitude spectra in measurements with ionizing radiation by low energy resolution detectors

Nikolay Artemiev

Instruments and Experimental Techniques, 2010

View PDFchevron_right

Relative fluorine concentrations in radio frequency/electron cyclotron resonance hybrid glow discharges

Michael Elta

Applied Physics Letters, 1992

View PDFchevron_right

Secondary scintillation yield in pure argon

C. M . B . Monteiro

Physics Letters B, 2008

View PDFchevron_right

Energy loss distribution in argon based gas detectors

Nilgün Demir

Turkish Atomic Energy Authority, 2000

View PDFchevron_right

Optical readout studies of the Thick-COBRA gaseous detector

Leszek Ropelewski

Journal of Instrumentation, 2021

View PDFchevron_right

GEM scintillation readout with avalanche photodiodes

C. M . B . Monteiro

Journal of Instrumentation, 2007

View PDFchevron_right

Optimization of a New Scintillation Gas Detector Used to Localize Electrons Emitted by 99mTc

Nicole Barthe, Claude Hennion

2000

View PDFchevron_right

Low X-Ray Energy Fluorescence Gas Electron Multiplier (GEM) for XAS Studies

Alan Chadwick

IEEE Transactions on Nuclear Science, 2007

View PDFchevron_right

Studies on Gas Mixture and Gas Recirculation Effects on GEM Detectors Operation at the CERN GIF++ Facility

Mara Corbetta

2019

View PDFchevron_right

Studies on fluorine-based impurity production in Triple-GEM detectors operated with CF4-based gas mixture

Mara Corbetta

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021

View PDFchevron_right

The gas proportional scintillation counter/microstrip gas chamber hybrid detector with argon filling

Diogo Freitas

Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment, 2002

View PDFchevron_right

Advances in gas avalanche radiation detectors for biomedical applications

Amos Breskin

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000

View PDFchevron_right

Characteristic of a PDP-based radiation detector in Xe-He mixture gas

Hyoseok Lee

2013

View PDFchevron_right

Reduction of ion backflow using a quadruple GEM detector with various gas mixtures

Sourav Tarafdar

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

View PDFchevron_right

Overlap of heavy charged particle tracks and the change in shape of optically stimulated luminescence curves of dosimeters

Stephen McKeever

Radiation Measurements, 2008

View PDFchevron_right

Gains, Uniformity and Signal Sharing in XY Readouts of the 10 cm × 10 cm Gas Electron Multiplier (GEM) Detector

Kiadtisak Saenboonruang

View PDFchevron_right

Effect of helium purity on the helium detector response in the saturation region of the detector field intensity

Everett Gibson

Journal of Chromatography A, 1981

View PDFchevron_right

Measurement of the photon spectrum from an X-ray tube above 10 keV using the induced XRF technique

Eliseo Vano

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1985

View PDFchevron_right