3D Finite Element Analysis of Two Modified Implant-Abutment Connections (original) (raw)
Effect of Dental Implant Cross-Sectional Design on Cortical Bone Structure Using Finite Element Analysis
Osama Abu-hammad
Clinical implant …, 2007
View PDFchevron_right
Finite Element Analysis of a New Dental Implant Design Optimized for the Desirable Stress Distribution in the Surrounding Bone Region
renzo guarnieri
Prosthesis
View PDFchevron_right
Effect of Different Abutments and Connections in Deformation Crestal Bone.
Mutlu Özcan
View PDFchevron_right
Comparison of Stress In Peri-Implant Bone of Anterior Maxilla on Loading of Straight and Angulated Platform Switched Implant Abutments - A 3D Finite Element Analysis
Shailesh Kumar
Archives of Clinical and Medical Case Reports, 2020
View PDFchevron_right
Evaluation of Stress Distribution Among Two Different Preangled Abutments of Implants in Two Different Densities of Bone at Different Levels Along the Implant–In Vitro Study
Ramesh Tirnati
The Journal of Contemporary Dental Practice, 2018
View PDFchevron_right
Influence of different implant-abutment connections on stress distribution in single tilted implants and peripheral bone: A three-dimensional finite element analysis
Özgür Öztürk
Bio-medical materials and engineering, 2018
View PDFchevron_right
Assessment of the stresses produced on the bone implant/tissue interface to the different insertion angulations of the implant - a three-dimensional analysis by the finite elements method
Juliana Ramacciato
Journal of Clinical and Experimental Dentistry
View PDFchevron_right
3D Finite Element Stress Analysis Of Different Abutment Materials in Screw, Implant and Cortical Bone
Amany Korsel
Egyptian Dental Journal
View PDFchevron_right
Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
Mauro Antonio de Arruda Nóbilo
Journal of Oral Implantology, 2015
View PDFchevron_right
To evaluate and compare the stress distribution pattern in the crestal bone around implants with various thread designs
Aakarshan dayal gupta
International journal of health sciences
View PDFchevron_right
Influence of Implant Collar Design on Stress and Strain Distribution in the Crestal Compact Bone: A Three-Dimensional Finite Element Analysis
Ming-Lun Hsu
2010
View PDFchevron_right
The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: A three-dimensional finite element analysis
Luigi Baggi
The Journal of Prosthetic Dentistry, 2008
View PDFchevron_right
Influence of dental implant designs on the strain at the peri-implant cortical bone: a finite element study
Michel Mesnard
Computer Methods in Biomechanics and Biomedical Engineering
View PDFchevron_right
Biomechanical analysis of different implant-abutments interfaces in different bone types: An in silico analysis
Fellippo Ramos Verri
Materials science & engineering. C, Materials for biological applications, 2018
View PDFchevron_right
Effect of different abutment materials of implant on stress distribution using three-dimensional finite element analysis
Raafat tamam
Medical Research Journal, 2013
View PDFchevron_right
Efficacy of Different Implant Abutment Materials onStress Distribution. (3D Finite Element Study)
Rami Galal
2019
View PDFchevron_right
Interactive Effects of Five Dental Implant Design Parameters on the Peak Strains at the Interfacial Bone: A Finite Element Study
Mahdi Kadkhodazadeh
The International Journal of Oral & Maxillofacial Implants
View PDFchevron_right
Finite Element Analysis of Stress in Bone and Abutment-Implant Interface under Static and Cyclic Loadings
SAIED NOKAR
Frontiers in dentistry, 2020
View PDFchevron_right
Comparative 3D finite element stress analysis of straight and angled wedge-shaped implant designs
Estevam Casas
The International journal of oral & maxillofacial implants
View PDFchevron_right
Stress Distribution Around Two Dental Implant Materials with New Designs: Comparative Finite Element Analysis Study
Faaiz Alhamdani
2021
View PDFchevron_right
Use of an Axisymmetric Finite Element Method to Compare Maxillary Bone Variables for a Loaded Implant
Amos Gilat
Journal of Prosthodontics, 1993
View PDFchevron_right
Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: A three-dimensional finite element analysis
Roxana Stegaroiu
Journal of Prosthodontic Research, 2010
View PDFchevron_right
Stress-Strain Distribution at Bone-Implant Interface Using 3D Finite Element Analysis
Durmuş Ali Bircan
2016
View PDFchevron_right
Biomechanical evaluation of different abutment-implant connections -A nonlinear finite element analysis
C.Y. Khor
View PDFchevron_right
Effects of the Implant Design on Peri- Implant Bone Stress and Abutment Micromovement: Three-Dimensional Finite Element Analysis of Original Computer-Aided Design Models
Satoshi Yamaguchi
Journal of Periodontology, 2014
View PDFchevron_right
The role of cortical zone level and prosthetic platform angle in dental implant mechanical response: A 3D finite element analysis
David C Watts
Dental Materials, 2021
View PDFchevron_right
Stress Analysis of Different Angulations of Implant Installation: The Finite Element Method
Heng-li Huang
The Kaohsiung Journal of Medical Sciences, 2008
View PDFchevron_right
Biomechanical Influence of Implant Neck Designs on Stress Distribution over Adjacent Bone: A Three-Dimensional Non-Linear Finite Element Analysis
AISYAH AHMAD SHAFI
IOP Conference Series: Materials Science and Engineering
View PDFchevron_right
Biomechanical Behavior of Implants with a Sloped Marginal Configuration
Barış Güncü
The International Journal of Prosthodontics
View PDFchevron_right
Biomechanical Evaluation of Bone Quality Effect on Stresses at Bone-Implant Interface: A Finite Element Study
abdelkrim aid
Applied and Computational Mechanics, 2020
View PDFchevron_right