3D Finite Element Analysis of Two Modified Implant-Abutment Connections (original) (raw)

Effect of Dental Implant Cross-Sectional Design on Cortical Bone Structure Using Finite Element Analysis

Osama Abu-hammad

Clinical implant …, 2007

View PDFchevron_right

Finite Element Analysis of a New Dental Implant Design Optimized for the Desirable Stress Distribution in the Surrounding Bone Region

renzo guarnieri

Prosthesis

View PDFchevron_right

Effect of Different Abutments and Connections in Deformation Crestal Bone.

Mutlu Özcan

View PDFchevron_right

Comparison of Stress In Peri-Implant Bone of Anterior Maxilla on Loading of Straight and Angulated Platform Switched Implant Abutments - A 3D Finite Element Analysis

Shailesh Kumar

Archives of Clinical and Medical Case Reports, 2020

View PDFchevron_right

Evaluation of Stress Distribution Among Two Different Preangled Abutments of Implants in Two Different Densities of Bone at Different Levels Along the Implant–In Vitro Study

Ramesh Tirnati

The Journal of Contemporary Dental Practice, 2018

View PDFchevron_right

Influence of different implant-abutment connections on stress distribution in single tilted implants and peripheral bone: A three-dimensional finite element analysis

Özgür Öztürk

Bio-medical materials and engineering, 2018

View PDFchevron_right

Assessment of the stresses produced on the bone implant/tissue interface to the different insertion angulations of the implant - a three-dimensional analysis by the finite elements method

Juliana Ramacciato

Journal of Clinical and Experimental Dentistry

View PDFchevron_right

3D Finite Element Stress Analysis Of Different Abutment Materials in Screw, Implant and Cortical Bone

Amany Korsel

Egyptian Dental Journal

View PDFchevron_right

Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study

Mauro Antonio de Arruda Nóbilo

Journal of Oral Implantology, 2015

View PDFchevron_right

To evaluate and compare the stress distribution pattern in the crestal bone around implants with various thread designs

Aakarshan dayal gupta

International journal of health sciences

View PDFchevron_right

Influence of Implant Collar Design on Stress and Strain Distribution in the Crestal Compact Bone: A Three-Dimensional Finite Element Analysis

Ming-Lun Hsu

2010

View PDFchevron_right

The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: A three-dimensional finite element analysis

Luigi Baggi

The Journal of Prosthetic Dentistry, 2008

View PDFchevron_right

Influence of dental implant designs on the strain at the peri-implant cortical bone: a finite element study

Michel Mesnard

Computer Methods in Biomechanics and Biomedical Engineering

View PDFchevron_right

Biomechanical analysis of different implant-abutments interfaces in different bone types: An in silico analysis

Fellippo Ramos Verri

Materials science & engineering. C, Materials for biological applications, 2018

View PDFchevron_right

Effect of different abutment materials of implant on stress distribution using three-dimensional finite element analysis

Raafat tamam

Medical Research Journal, 2013

View PDFchevron_right

Efficacy of Different Implant Abutment Materials onStress Distribution. (3D Finite Element Study)

Rami Galal

2019

View PDFchevron_right

Interactive Effects of Five Dental Implant Design Parameters on the Peak Strains at the Interfacial Bone: A Finite Element Study

Mahdi Kadkhodazadeh

The International Journal of Oral & Maxillofacial Implants

View PDFchevron_right

Finite Element Analysis of Stress in Bone and Abutment-Implant Interface under Static and Cyclic Loadings

SAIED NOKAR

Frontiers in dentistry, 2020

View PDFchevron_right

Comparative 3D finite element stress analysis of straight and angled wedge-shaped implant designs

Estevam Casas

The International journal of oral & maxillofacial implants

View PDFchevron_right

Stress Distribution Around Two Dental Implant Materials with New Designs: Comparative Finite Element Analysis Study

Faaiz Alhamdani

2021

View PDFchevron_right

Use of an Axisymmetric Finite Element Method to Compare Maxillary Bone Variables for a Loaded Implant

Amos Gilat

Journal of Prosthodontics, 1993

View PDFchevron_right

Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: A three-dimensional finite element analysis

Roxana Stegaroiu

Journal of Prosthodontic Research, 2010

View PDFchevron_right

Stress-Strain Distribution at Bone-Implant Interface Using 3D Finite Element Analysis

Durmuş Ali Bircan

2016

View PDFchevron_right

Biomechanical evaluation of different abutment-implant connections -A nonlinear finite element analysis

C.Y. Khor

View PDFchevron_right

Effects of the Implant Design on Peri- Implant Bone Stress and Abutment Micromovement: Three-Dimensional Finite Element Analysis of Original Computer-Aided Design Models

Satoshi Yamaguchi

Journal of Periodontology, 2014

View PDFchevron_right

The role of cortical zone level and prosthetic platform angle in dental implant mechanical response: A 3D finite element analysis

David C Watts

Dental Materials, 2021

View PDFchevron_right

Stress Analysis of Different Angulations of Implant Installation: The Finite Element Method

Heng-li Huang

The Kaohsiung Journal of Medical Sciences, 2008

View PDFchevron_right

Biomechanical Influence of Implant Neck Designs on Stress Distribution over Adjacent Bone: A Three-Dimensional Non-Linear Finite Element Analysis

AISYAH AHMAD SHAFI

IOP Conference Series: Materials Science and Engineering

View PDFchevron_right

Biomechanical Behavior of Implants with a Sloped Marginal Configuration

Barış Güncü

The International Journal of Prosthodontics

View PDFchevron_right

Biomechanical Evaluation of Bone Quality Effect on Stresses at Bone-Implant Interface: A Finite Element Study

abdelkrim aid

Applied and Computational Mechanics, 2020

View PDFchevron_right