Evaluation of the Fluorescence of Composite Resins Under an Ultraviolet Light Source (original) (raw)

In vitro evaluation of composite resin fluorescence after natural aging

Journal of Clinical and Experimental Dentistry, 2020

Background: Some composite resins contain luminophorous agents in order to reproduce tooth fluorescence. The objective of this study was to compare the fluorescence spectra emitted by composite resins with those of human enamel and dentin, and their emission behaviour after a 90-day natural aging period. Material and Methods: Nine shades of the composite resins Z350XT/3M (XT), Opallis/FGM (OP) and Empress Direct/Ivoclar-Vivadent (ED) were analyzed. Five specimens (10.0 mm x 2.0mm) were fabricated for each shade. Enamel (5.0 mm x 0.30 mm) and dentin (5.0 mm x 1.0 mm) specimens were obtained from sound human third molars. Fluorescence spectra of human dentin and enamel as well as the composite specimens immediately after fabrication were measured at the excitation peaks of 375, 395 and 410 nm. To assess composite resin fluorescence intensity changes over time, measurements were conducted after 30, 60 and 90 days, at 395 nm. Differences in fluorescence intensity over time were analyzed with ANOVA and Tukey's test (p<0.05). Results: Fluorescence spectra baseline values of composites demonstrated no differences in intensity among the excitation peaks tested, with maximum emission found at the peak of 450 nm. Enamel and dentin spectra varied with different excitations, and the greater the excitation, the longer the wavelength in comparison to composite resins. After 90 days, XT presented an increase in fluorescence intensity, while OP and ED showed a reduction when compared with baseline values. Conclusions: Fluorescence intensity of composite resins changed during the period analyzed, with an emission behavior different from that of human enamel and dentin. The main changes occurred in the first 30 days.

Effect of thickness on fluorescence of resin-composites and dental substrates

Brazilian Dental Science, 2016

Objective: This study evaluated the effect of thickness on fluorescence of resin composites and tooth substrates (enamel and dentin). Material and methods: Ninety bovine incisors were used, resulting in 45 dentin and 45 enamel disks (6 mm diameter and 0.5, 1, or 1.5 mm in thickness). Ninety discs of Charisma, Filtek Z350 and IPS Empress Direct (for enamel and dentin) resins at same dimensions were built. Fluorescence measurements were performed using a fluorescence spectrophotometer (RF-5301PC, Shimadzu Corp) with excitation at 365 nm. Data were submitted to 2-way ANOVA and Tukey’s post hoc tests (? = 0.05). Results: The 2- way - ANOVA revealed statistically significant differences for all factors, as well as the interaction between them (p <0.05). Dentin specimens (1.5 mm) showed highest fluorescence (128.33 A.U.), while Filtek Z350 (dentin - 1.0 mm) showed the lowest fluorescence (29.84 A.U.). Thickness influenced fluorescence values of enamel substrate. Conclusion: The thickne...

A new methodology for fluorescence analysis of composite resins used in anterior direct restorations

General dentistry

The aim of this study was to use a new methodology to evaluate the fluorescence of composite resins for direct restorations. Microhybrid (group 1, Amelogen; group 2, Opallis; group 3, Filtek Z250) and nanohybrid (group 4, Filtek Z350 XT; group 5, Brilliant NG; group 6, Evolu-X) composite resins were analyzed in this study. A prefabricated matrix was used to prepare 60 specimens of 7.0 × 3.0 mm (n = 10 per group); the composite resin discs were prepared in 2 increments (1.5 mm each) and photocured for 20 seconds. To establish a control group of natural teeth, 10 maxillary central incisor crowns were horizontally sectioned to create 10 discs of dentin and enamel tissues with the same dimensions as the composite resin specimens. The specimens were placed in a box with ultraviolet light, and photographs were taken. Aperture 3.0 software was used to quantify the central portion of the image of each specimen in shades of red (R), green (G), and blue (B) of the RGB color space. The brighte...

Quantitative and Qualitative Assessment of Fluorescence in Aesthetic Direct Restorations

Materials

Currently available direct restoration materials have been developed to have improved optical properties to interact with light in the same manner as the natural tooth. The objective of this study was to investigate the fluorescence of different enamel resin composites. In the present study, nine brands of enamel composites were tested in vitro, some of which are cited by manufacturers as having color adjustment potential. Fluorescence spectra of the composite specimens and the human natural enamel were measured with a fluorescence spectrophotometer immediately after preparation and after 6 months. Qualitative data of the specimens were also collected. Statistical analyses were conducted by Kruskal–Wallis and Mann–Whitney U nonparametric tests (p < 0.05). Almost all tested resin composites presented a significant decrease in the fluorescence values after a period of 6 months. There was no significant decrease in fluorescence in the case of Harmonize™ resin composite samples, whic...

Fluorescence intensities of composite resins on photo images

Odontology, 2021

Recording fluorescence using flash photography, may help reduce time of capture and apply effectively in clinical practice. To test methods for visualizing composite resins fluorescence by direct digital photography. Sixty-four specimen discs (1.5 × 10 mm) were prepared from 8 different composite resin brands. Their CIELAB color coordinates (L*, a*, b*) and fluorescence were measured using a portable colorimeter and a fluorescence spectrophotometer. The mean of three measurements was recorded and then specimens were photographed by a DSLR camera with two different filters (365 nm and 405 nm) mounted on a commercial macro flash. RGB values of all specimens on the photographs were measured by using Photoshop software and converted to CIELab. Data were then analyzed using Kruskal–Wallis and Dunn’s multiple comparisons tests. Correlation and regression analyses were also used to relate fluorescence and color parameters on the photographs at α = 0.05. Fluorescence and color data indicate...

Direct Spectrometry: A New Alternative for Measuring the Fluorescence of Composite Resins and Dental Tissues

Operative Dentistry, 2014

SUMMARY The aim of this study was to evaluate the fluorescence intensity of different composite resins and compare those values with the fluorescence intensity of dental tissues. Different composite resins were used to make 10 discs (2 mm in depth and 4 mm in diameter) of each brand, divided into groups: 1) Z (Filtek Z350, 3M ESPE), 2) ES (Esthet-X, Dentsply), 3) A (Amelogen Plus, Ultradent), 4) DVS (Durafill-VS, Heraeus Kulzer) with 2 mm composite resin for enamel (A2), 5) OES ([Esthet-X] opaque-OA [1 mm] + enamel-A2 [1 mm]); 6) ODVSI ([Charisma-Opal/Durafill-VSI], opaque-OM (1 mm) + translucent [1mm]), and 7) DVSI ([Durafill- VSI] translucent [2 mm]). Dental tissue specimens were obtained from human anterior teeth cut in a mesiodistal direction to obtain enamel, dentin, and enamel/dentin samples (2 mm). The fluorescence intensity of specimens was directly measured using an optic fiber associated with a spectrometer (Ocean Optics USB 4000) and recorded in graphic form (Origin 8.0 p...