Modular junction may be more problematic than bearing wear in metal-on-metal total hip arthroplasty (original) (raw)

Metal ion trend in patients with metal-on-metal total hip arthroplasty: a 10-year prospective study

claudio carlo castelli

HIP International, 2018

View PDFchevron_right

What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces

Brian T Barlow

Journal of Arthroplasty, 2017

View PDFchevron_right

Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty

Richard Villar

The Journal of bone and joint surgery. British volume, 2003

View PDFchevron_right

Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems

James Powell

Journal of Orthopaedic Surgery and Research, 2014

View PDFchevron_right

Metal Ion Release, Clinical and Radiological Outcomes in Large Diameter Metal-on-Metal Total Hip Arthroplasty at Long-Term Follow-Up

Assunta Pozzuoli

Diagnostics

View PDFchevron_right

No association between serum metal ions and implant fixation in large-head metal-on-metal total hip arthroplasty

Stig Jakobsen

Acta Orthopaedica, 2014

View PDFchevron_right

Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements

Thomas Szekeres

Journal of Orthopaedic Research, 2003

View PDFchevron_right

The Effect Of Different Bearing Surfaces On Metal Ion Levels In Urine Following 28 Mm Metal-On-Metal And 28 Mm Metal-On-Polyethylene Total Hip Arthroplasty

Maija Pesola

Scandinavian Journal of Surgery, 2013

View PDFchevron_right

Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties: A literature overview

Jes Lauritzen

2013

View PDFchevron_right

Metal ion levels after metal-on-metal Ring total hip replacement

Tasleem khan

The Journal of Bone and Joint Surgery. British volume, 2007

View PDFchevron_right

Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern

P. Oger, C. Delaunay, P. Vendittoli

2010

View PDFchevron_right

Modular implant design affects metal ion release following metal-on-metal hip arthroplasty: a retrospective study on 75 cases

Luigi La Barbera

Journal of Biological Regulators and Homeostatic Agents, 2019

View PDFchevron_right

The Relationship Between Cobalt/Chromium Ratios and the High Prevalence of Head-Stem Junction Corrosion in Metal-on-Metal Total Hip Arthroplasty

Gordon Blunn

The Journal of Arthroplasty, 2016

View PDFchevron_right

Metal Ion Levels Not Sufficient as a Screening Measure for Adverse Reactions in Metal-on-Metal Hip Arthroplasties

James Wimhurst

The Journal of Arthroplasty, 2013

View PDFchevron_right

Adverse reaction to metal debris following hip resurfacing: THE INFLUENCE OF COMPONENT TYPE, ORIENTATION AND VOLUMETRIC WEAR

Thomas Joyce

Journal of Bone and Joint Surgery - British Volume, 2011

View PDFchevron_right

Ten-Year Outcome of Serum Metal Ion Levels After Primary Total Hip Arthroplasty

Brett Levine

The Journal of Bone and Joint Surgery (American), 2013

View PDFchevron_right

Serum-Cobalt Levels with Metal-on-Metal Bearings in the Cement-Free Total Hip Arthroplasty Results Covering Two Years; Prospective Study

Alexander Grübl

Acta Chirurgiae Orthopaedicae Et Traumatologiae Cechoslovaca, 2011

View PDFchevron_right

An analysis of metal ion levels in the joint fluid of symptomatic patients with metal-on-metal hip replacements

Barry Sampson

The Journal of bone and joint surgery. British volume, 2011

View PDFchevron_right

Cobalt and Chromium Measurement in Patients with Metal Hip Prostheses

Alister Hart

Clinical Chemistry, 2013

View PDFchevron_right

Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty-Preliminary results of a prospective five year study after two years of follow-up

Andreas Leithner

BMC Musculoskeletal Disorders, 2012

View PDFchevron_right

Equally low blood metal ion levels at 10-years follow up of total hip arthroplasties with Oxinium, CoCrMo and stainless steel femoral heads. Data from a randomized clinical trial

Anne Marie Fenstad

2022

View PDFchevron_right

Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty

Nasir awan

Irish journal of medical science, 2018

View PDFchevron_right

Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses

Andrea Trevisan

Medicina, 2021

View PDFchevron_right

Adverse Wear in MOM Hip-Arthroplasty Related to the Production of Metal Fragments at Impingement Sites

Jean yves Lazennec

Open Journal of Orthopedics, 2018

View PDFchevron_right

Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

Rinne Peters

Case Reports in Orthopedics, 2017

View PDFchevron_right

A consensus paper on metal ions in metal-on-metal hip arthroplasties

Joshua Jacobs

Journal of Arthroplasty, 2004

View PDFchevron_right

Metal ion levels after metal-on-metal proximal femoral replacements: A 30-YEAR FOLLOW-UP

Paul Unwin

Journal of Bone and Joint Surgery - British Volume, 2005

View PDFchevron_right

The Relationship Between Cobalt/Chromium Ratios and the High Prevalence of Head-Stem Junction Corrosion in Metal-on-Metal Total Hip Arthroplasty Taper corrosion of hip implants View project Retrieval Analysis of Beyond Compliance Implants View project

Harry Hothi

View PDFchevron_right

Metal ion levels after metal-on-metal proximal femoral replacements

Gordon Blunn

The Journal of Bone and Joint Surgery. British volume, 2005

View PDFchevron_right