Marco Antonio Bottino - Academia.edu (original) (raw)
Papers by Marco Antonio Bottino
Brazilian Dental Science, Aug 8, 2012
Braz Dent Sci 2011 jul./dez.; 14 (3/4) 4-11 4 Martinelli et al.
General Dentistry, 2008
This study sought to investigate the surface roughness and the S ence of Streptococcus mutans (in... more This study sought to investigate the surface roughness and the S ence of Streptococcus mutans (in the presence and absence of saliva) to ceramics and composites. The early dental biofilms formed in situ on the materials were illustrated, using scanning electron ascopy (SEM). Feldspathic and leucite/feldspathic ceramics and microhybrid and microfilled composites were evaluated. Human dental enamel was used as the control. Standardized specimens of the miaterials were produced and surface roughness was analyzed. The dhesion tests were carried out in 24-well plates and colony forming units (CFU/mL) were evaluated. Values of roughness (microm) ,adherence (CFU/mL) were analyzed statistically. Of all the surfaces tested, enamel was the roughest. Leucite/feldspathic ceramics were rougher than the feldspathic ceramic, while composites were similar statistically. Enamel offered the highest level of adherence to uncoated and saliva-coated specimens, while the leucite/feldspathic ceramic demonstrated greater adherence than the feldspathic ceramic and the composites were similar statically. The rougher restorative materials increased the adherence of S. mutans on the material surfaces.
Revista Ibero Americana De Protese Clinica Laboratical, Jun 9, 2010
Abstract Para a observação da alteração dimensional em técnicas de impressão de única e dupla fas... more Abstract Para a observação da alteração dimensional em técnicas de impressão de única e dupla fase com silicone de adição, foi fundido um modelo padrão de hemiarco simulando um caso de prótese fixa com dois suportes (45 e 47), com perfurações esféricas oclusais ...
Revista Brasileira De Otorrinolaringologia, 2003
The International Journal of Oral & Maxillofacial Implants, 2015
To determine the effect of maintaining torque after mechanical cycling of abutment screws that ar... more To determine the effect of maintaining torque after mechanical cycling of abutment screws that are coated with diamondlike carbon and coated with diamondlike carbon doped with diamond nanoparticles, with external and internal hex connections. Sixty implants were divided into six groups according to the type of connection (external or internal hex) and the type of abutment screw (uncoated, coated with diamondlike carbon, and coated with diamondlike carbon doped with diamond nanoparticles). The implants were inserted into polyurethane resin and crowns of nickel chrome were cemented on the implants. The crowns had a hole for access to the screw. The initial torque and the torque after mechanical cycling were measured. The torque values maintained (in percentages) were evaluated. Statistical analysis was performed using one-way analysis of variance and the Tukey test, with a significance level of 5%. The largest torque value was maintained in uncoated screws with external hex connections, a finding that was statistically significant (P = .0001). No statistically significant differences were seen between the groups with and without coating in maintaining torque for screws with internal hex connections (P = .5476). After mechanical cycling, the diamondlike carbon with and without diamond doping on the abutment screws showed no improvement in maintaining torque in external and internal hex connections.
Journal of prosthodontics : official journal of the American College of Prosthodontists, Jan 5, 2015
In testing adhesion using shear bond test, a combination of shear and tensile forces occur at the... more In testing adhesion using shear bond test, a combination of shear and tensile forces occur at the interface, resulting in complex stresses. The jig designs used for this kind of test show variations in published studies, complicating direct comparison between studies. This study evaluated the effect of different jig designs on metal-ceramic bond strength and assessed the stress distribution at the interface using finite element analysis (FEA). Metal-ceramic (Metal: Ni-Cr, Wiron 99, Bego; Ceramic: Vita Omega 900, Vita) specimens (N = 36) (diameter: 4 mm, veneer thickness: 4 mm; base diameter: 5 mm, thickness: 1 mm) were fabricated and randomly divided into three groups (n = 12 per group) to be tested using one of the following jig designs: (a) chisel (CH) (ISO 11405), (b) steel strip (SS), (c) piston (PI). Metal-ceramic interfaces were loaded under shear until debonding in a universal testing machine (0.5 mm/min). Failure types were evaluated using scanning electron microscopy (SEM)....
Journal of applied biomaterials & functional materials, Jan 18, 2015
This study evaluated the effect of air abrasion and polishing regimens on the flexural strength o... more This study evaluated the effect of air abrasion and polishing regimens on the flexural strength of yttrium stabilized polycrystalline tetragonal zirconia (Y-TZP). From Y-TZP blocks (InCeram 2000 YZ Cubes; Vita Zahnfabrik, Bad Säckingen, Germany) 120 bars (25 mm × 4 mm × 1.2 mm) were obtained according to ISO 6872:2008 and randomly divided into 4 groups: Group C: (control) without surface treatment (n = 30); Group APA: Air abrasion with aluminum oxide (44 µm) (n = 30); Group SC: Silica-coating (CoJet, 30 µm) (n = 30); Group FD: Fine diamond bur (n = 30). Subsequently, all specimens were subjected to 4-point bending test (in distilled water at 37°C) in a universal testing machine (EMIC DL 1000; São José dos Pinhais, Paraná, Brazil); cross-head speed: 0.5 mm/min). The characteristic strength (σ0) of each specimen was obtained from the flexural strength test and evaluated using Weibull analysis. X-ray diffraction analysis was utilized to quantity the monoclinic phase. The surface topogr...
Full-contour yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations have started... more Full-contour yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations have started to be advocated in clinical situations where occlusal/palatal space is limited or to withstand parafunctional activities. Objectives: To investigate the effects of different polishing techniques on the surface roughness of Y-TZP (Ardent Dental, Inc) and on the wear behavior of synthetic hydroxyapatite (HA) utilized herein as a substitute for human enamel. Methods: Thirty-two Y-TZP sliders (ϕ=2mm×1.5mm in height) were manufactured using CAD/CAM and embedded in acrylic resin using brass holders. Samples were then randomly allocated into four groups (n=8) according to the finishing/polishing procedure: G1-as-machined, G2-glazed, G3-diamond bur finishing (Brasseler, USA) and G4-G3+OptraFine® polishing kit (Ivoclar-Vivadent). Thirty-two sintered HA disks (ϕ=11mm×2.9mm in height) were mounted in brass holders as previously described. Baseline surface roughness (Ra and Rq, in µm) were recorded...
We present an analysis of the foreground emission present in the WMAP 3-year data as determined b... more We present an analysis of the foreground emission present in the WMAP 3-year data as determined by the method of Independent Component Analysis. We derived coupling coefficients between the WMAP data and foreground templates which are then used to infer the spectral behaviour for three foreground components -- synchrotron, anomalous dust-correlated emission and free-free. For the first two components, we
In this paper, we present a foreground analysis of the WMAP 5-year data using the FASTICA algorit... more In this paper, we present a foreground analysis of the WMAP 5-year data using the FASTICA algorithm, improving on the treatment of the WMAP 3-year data in Bottino et al 2008. We revisit the nature of the free-free spectrum with the emphasis on attempting to confirm or otherwise the spectral feature claimed in Dobbler et al 2008b and explained in
Frontiers of oral biology, 2015
Periodontitis is a chronic inflammatory disorder affecting nearly 50% of adults in the United Sta... more Periodontitis is a chronic inflammatory disorder affecting nearly 50% of adults in the United States. If left untreated, it can lead to the destruction of both soft and mineralized tissues that constitute the periodontium. Clinical management, including but not limited to flap debridement and/or curettage, as well as regenerative-based strategies with periodontal membranes associated or not with grafting materials, has been used with distinct levels of success. Unquestionably, no single implantable biomaterial can consistently guide the coordinated growth and development of multiple tissue types, especially in very large periodontal defects. With the global aging population, it is extremely important to find novel biomaterials, particularly bioactive membranes and/or scaffolds, for guided tissue (GTR) and bone regeneration (GBR) to aid in the reestablishment of the health and function of distinct periodontal tissues. This chapter offers an update on the evolution of biomaterials (i....
Operative Dentistry, 2009
Objectives: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutraliza... more Objectives: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutralization and fatigue load cycling performed on human premolars restored with ceramic inlays had an influence on microtensile bond strength results (MTBS). Methods: MOD inlay preparations were performed in 40 premolars (with their roots embedded in acrylic resin). Forty ceramic restorations were prepared using glass-ceramic (IPS Empress). The inner surfaces of all the restorations were etched with 10% hydrofluoric acid for 60 seconds, rinsed with water and dried.
Revista Brasileira de Otorrinolaringologia
As vestibulopatias atribuídas aos distúrbios do metabolismo do açúcar são ainda hoje um tema cont... more As vestibulopatias atribuídas aos distúrbios do metabolismo do açúcar são ainda hoje um tema controverso na literatura pela falta de demonstração objetiva que relacione causa e efeito. OBJETIVO: Nosso objetivo é relatar os resultados seriados do Teste de Integração Sensorial no acompanhamento dos pacientes portadores de DMA tratados com dieta fracionada e restrição de glicose. FORMA DE ESTUDO: Retrospectivo, inclui um desenho de descrição de casos. MÉTODO: Foram avaliadas as respostas de 21 pacientes portadores de distúrbios do metabolismo do açúcar e tontura submetidos à dieta fracionada com restrição de glicose. A medição objetiva do equilíbrio corporal dos pacientes foi feita pela Posturografia Dinâmica Computadorizada, utilizando-se o protocolo do Teste de Integração Sensorial. RESULTADOS: Após a instituição da dieta, observou-se melhora objetiva significante nas condições que retratam a função vestibular e o equilíbrio corporal dos indivíduos estudados. CONCLUSÃO: Concluímos qu...
Dental Materials, 2015
to evaluate the influence of the occlusal resin cement thickness on the cyclic loads-to-failure o... more to evaluate the influence of the occlusal resin cement thickness on the cyclic loads-to-failure of feldspathic crowns and to compare the results to data from monotonic tests. A large range of cement thickness (50μm and 500μm) was tested, in order to better measure the influence of this variable. Feldspathic ceramic crowns (Vita Mark II blocks, Vita Zahnfabrik) were bonded to dentin analog dies (G10 (NEMA grade G10, International Paper), with occlusal resin cement thicknesses of 50μm and 500μm (Multilink Automix, Ivoclar). The dies were prepared with microchannels for water transport to the cement layer. After 96-h water storage, the specimens (n=20) were submitted to cyclic loads (500,000 cycles at 20Hz; initial maximum load=40% of monotonic load, from previous data) following a staircase sensitivity design (step size=25N). Failure loads at 500,000 cycles were compared to monotonic failure loads (from a previous study with specimens produced by the same author, using the same materials, specimen configuration and cementation protocol). Crowns with an occlusal cement layer of 50μm were more resistant than those cemented with 500μm (246.4±22.9N vs. 158.9±22.9N), under wet cyclic testing conditions (p<0.001). The fatigue failure loads were reduced compared to monotonic loads: to 37% of monotonic for 50μm; to 53% of monotonic for 500μm. An occlusal cement thickness of 50μm was more favorable for the structural performance of feldspathic crowns than was 500μm. Cyclic fatigue reduced failure loads well below those found under monotonic loading.
Journal of biomedical materials research. Part B, Applied biomaterials, Jan 7, 2015
Composite fibrous electrospun membranes based on poly(dl-lactide) (PLA) and poly(ε-caprolactone) ... more Composite fibrous electrospun membranes based on poly(dl-lactide) (PLA) and poly(ε-caprolactone) (PCL) were engineered to include borate bioactive glass (BBG) for the potential purposes of guided bone regeneration (GBR). The fibers were characterized using scanning and transmission electron microscopies, which respectively confirmed the submicron fibrous arrangement of the membranes and the successful incorporation of BBG particles. Selected mechanical properties of the membranes were evaluated using the suture pullout test. The addition of BBG at 10 wt % led to similar stiffness, but more importantly, it led to a significantly stronger (2.37 ± 0.51 N mm) membrane when compared with the commercially available Epiguide® (1.06 ± 0.24 N mm) under hydrated conditions. Stability (shrinkage) was determined after incubation in a phosphate buffer solution from 24 h up to 9 days. The dimensional stability of the PLA:PCL-based membranes with or without BBG incorporation (10.07-16.08%) was sim...
Dental Materials, 2015
To evaluate the effects of hard machining, glaze firing and hydrofluoric acid etching on the biax... more To evaluate the effects of hard machining, glaze firing and hydrofluoric acid etching on the biaxial flexural strength and roughness of a CAD/CAM leucite glass-ceramic; to investigate if ceramic post-machining surface roughness is influenced by the machining order and by the pair of burs used for it. A hundred forty four discs were machined by six nominally identical pairs of burs and divided into groups (n=24): (1) machining-M, (2) machining and glaze firing-MG, (3) machining and hydrofluoric acid etching-MA, (4) machining, glaze firing and hydrofluoric acid etching-MGA, (5) machining followed by polishing, as a control-MP, (6) machining, polishing and hydrofluoric acid etching-MPA. The roughness after each treatment (Ra and Rz) was measured. The discs were submitted to a piston-on-three ball flexure test (ISO 6872/2008) and strength data analyzed through Weibull statistics (95% CI). M resulted in lower characteristic strength (σ0) (128.2MPa) than MP (177.2MPa). The glaze firing reduced σ0 (109MPa), without affecting roughness. Hydrofluoric acid etching increased the roughness without affecting σ0. Spearman's coefficient (rs) indicated strong and significant correlation between machining order and roughness (rsRa=-0.66; rsRz=-0.73). The ceramic post-machining surface roughness differed significantly according to the pair of burs employed (p<0.05). hard machining and glaze firing reduced the leucite ceramic strength, while hydrofluoric acid etching did not affect the strength. Variability in the roughness might be expected after machining, since it was influenced by the machining order and by the bur pairing.
Journal of endodontics, Jan 24, 2015
Actinomyces naeslundii has been recovered from traumatized permanent teeth diagnosed with necroti... more Actinomyces naeslundii has been recovered from traumatized permanent teeth diagnosed with necrotic pulps. In this work, a triple antibiotic paste (TAP)-mimic scaffold is proposed as a drug-delivery strategy to eliminate A. naeslundii dentin biofilm. Metronidazole, ciprofloxacin, and minocycline were added to a polydioxanone (PDS) polymer solution and spun into fibrous scaffolds. Fiber morphology, mechanical properties, and drug release were investigated by using scanning electron microscopy, microtensile testing, and high-performance liquid chromatography, respectively. Human dentin specimens (4 × 4 × 1 mm(3), n = 4/group) were inoculated with A. naeslundii (ATCC 43146) for 7 days for biofilm formation. The infected dentin specimens were exposed to TAP-mimic scaffolds, TAP solution (positive control), and pure PDS (drug-free scaffold). Dentin infected (7-day biofilm) specimens were used for comparison (negative control). Confocal laser scanning microscopy was done to determine bacte...
Brazilian journal of otorhinolaryngology
Brazilian Dental Science, Aug 8, 2012
Braz Dent Sci 2011 jul./dez.; 14 (3/4) 4-11 4 Martinelli et al.
General Dentistry, 2008
This study sought to investigate the surface roughness and the S ence of Streptococcus mutans (in... more This study sought to investigate the surface roughness and the S ence of Streptococcus mutans (in the presence and absence of saliva) to ceramics and composites. The early dental biofilms formed in situ on the materials were illustrated, using scanning electron ascopy (SEM). Feldspathic and leucite/feldspathic ceramics and microhybrid and microfilled composites were evaluated. Human dental enamel was used as the control. Standardized specimens of the miaterials were produced and surface roughness was analyzed. The dhesion tests were carried out in 24-well plates and colony forming units (CFU/mL) were evaluated. Values of roughness (microm) ,adherence (CFU/mL) were analyzed statistically. Of all the surfaces tested, enamel was the roughest. Leucite/feldspathic ceramics were rougher than the feldspathic ceramic, while composites were similar statistically. Enamel offered the highest level of adherence to uncoated and saliva-coated specimens, while the leucite/feldspathic ceramic demonstrated greater adherence than the feldspathic ceramic and the composites were similar statically. The rougher restorative materials increased the adherence of S. mutans on the material surfaces.
Revista Ibero Americana De Protese Clinica Laboratical, Jun 9, 2010
Abstract Para a observação da alteração dimensional em técnicas de impressão de única e dupla fas... more Abstract Para a observação da alteração dimensional em técnicas de impressão de única e dupla fase com silicone de adição, foi fundido um modelo padrão de hemiarco simulando um caso de prótese fixa com dois suportes (45 e 47), com perfurações esféricas oclusais ...
Revista Brasileira De Otorrinolaringologia, 2003
The International Journal of Oral & Maxillofacial Implants, 2015
To determine the effect of maintaining torque after mechanical cycling of abutment screws that ar... more To determine the effect of maintaining torque after mechanical cycling of abutment screws that are coated with diamondlike carbon and coated with diamondlike carbon doped with diamond nanoparticles, with external and internal hex connections. Sixty implants were divided into six groups according to the type of connection (external or internal hex) and the type of abutment screw (uncoated, coated with diamondlike carbon, and coated with diamondlike carbon doped with diamond nanoparticles). The implants were inserted into polyurethane resin and crowns of nickel chrome were cemented on the implants. The crowns had a hole for access to the screw. The initial torque and the torque after mechanical cycling were measured. The torque values maintained (in percentages) were evaluated. Statistical analysis was performed using one-way analysis of variance and the Tukey test, with a significance level of 5%. The largest torque value was maintained in uncoated screws with external hex connections, a finding that was statistically significant (P = .0001). No statistically significant differences were seen between the groups with and without coating in maintaining torque for screws with internal hex connections (P = .5476). After mechanical cycling, the diamondlike carbon with and without diamond doping on the abutment screws showed no improvement in maintaining torque in external and internal hex connections.
Journal of prosthodontics : official journal of the American College of Prosthodontists, Jan 5, 2015
In testing adhesion using shear bond test, a combination of shear and tensile forces occur at the... more In testing adhesion using shear bond test, a combination of shear and tensile forces occur at the interface, resulting in complex stresses. The jig designs used for this kind of test show variations in published studies, complicating direct comparison between studies. This study evaluated the effect of different jig designs on metal-ceramic bond strength and assessed the stress distribution at the interface using finite element analysis (FEA). Metal-ceramic (Metal: Ni-Cr, Wiron 99, Bego; Ceramic: Vita Omega 900, Vita) specimens (N = 36) (diameter: 4 mm, veneer thickness: 4 mm; base diameter: 5 mm, thickness: 1 mm) were fabricated and randomly divided into three groups (n = 12 per group) to be tested using one of the following jig designs: (a) chisel (CH) (ISO 11405), (b) steel strip (SS), (c) piston (PI). Metal-ceramic interfaces were loaded under shear until debonding in a universal testing machine (0.5 mm/min). Failure types were evaluated using scanning electron microscopy (SEM)....
Journal of applied biomaterials & functional materials, Jan 18, 2015
This study evaluated the effect of air abrasion and polishing regimens on the flexural strength o... more This study evaluated the effect of air abrasion and polishing regimens on the flexural strength of yttrium stabilized polycrystalline tetragonal zirconia (Y-TZP). From Y-TZP blocks (InCeram 2000 YZ Cubes; Vita Zahnfabrik, Bad Säckingen, Germany) 120 bars (25 mm × 4 mm × 1.2 mm) were obtained according to ISO 6872:2008 and randomly divided into 4 groups: Group C: (control) without surface treatment (n = 30); Group APA: Air abrasion with aluminum oxide (44 µm) (n = 30); Group SC: Silica-coating (CoJet, 30 µm) (n = 30); Group FD: Fine diamond bur (n = 30). Subsequently, all specimens were subjected to 4-point bending test (in distilled water at 37°C) in a universal testing machine (EMIC DL 1000; São José dos Pinhais, Paraná, Brazil); cross-head speed: 0.5 mm/min). The characteristic strength (σ0) of each specimen was obtained from the flexural strength test and evaluated using Weibull analysis. X-ray diffraction analysis was utilized to quantity the monoclinic phase. The surface topogr...
Full-contour yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations have started... more Full-contour yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations have started to be advocated in clinical situations where occlusal/palatal space is limited or to withstand parafunctional activities. Objectives: To investigate the effects of different polishing techniques on the surface roughness of Y-TZP (Ardent Dental, Inc) and on the wear behavior of synthetic hydroxyapatite (HA) utilized herein as a substitute for human enamel. Methods: Thirty-two Y-TZP sliders (ϕ=2mm×1.5mm in height) were manufactured using CAD/CAM and embedded in acrylic resin using brass holders. Samples were then randomly allocated into four groups (n=8) according to the finishing/polishing procedure: G1-as-machined, G2-glazed, G3-diamond bur finishing (Brasseler, USA) and G4-G3+OptraFine® polishing kit (Ivoclar-Vivadent). Thirty-two sintered HA disks (ϕ=11mm×2.9mm in height) were mounted in brass holders as previously described. Baseline surface roughness (Ra and Rq, in µm) were recorded...
We present an analysis of the foreground emission present in the WMAP 3-year data as determined b... more We present an analysis of the foreground emission present in the WMAP 3-year data as determined by the method of Independent Component Analysis. We derived coupling coefficients between the WMAP data and foreground templates which are then used to infer the spectral behaviour for three foreground components -- synchrotron, anomalous dust-correlated emission and free-free. For the first two components, we
In this paper, we present a foreground analysis of the WMAP 5-year data using the FASTICA algorit... more In this paper, we present a foreground analysis of the WMAP 5-year data using the FASTICA algorithm, improving on the treatment of the WMAP 3-year data in Bottino et al 2008. We revisit the nature of the free-free spectrum with the emphasis on attempting to confirm or otherwise the spectral feature claimed in Dobbler et al 2008b and explained in
Frontiers of oral biology, 2015
Periodontitis is a chronic inflammatory disorder affecting nearly 50% of adults in the United Sta... more Periodontitis is a chronic inflammatory disorder affecting nearly 50% of adults in the United States. If left untreated, it can lead to the destruction of both soft and mineralized tissues that constitute the periodontium. Clinical management, including but not limited to flap debridement and/or curettage, as well as regenerative-based strategies with periodontal membranes associated or not with grafting materials, has been used with distinct levels of success. Unquestionably, no single implantable biomaterial can consistently guide the coordinated growth and development of multiple tissue types, especially in very large periodontal defects. With the global aging population, it is extremely important to find novel biomaterials, particularly bioactive membranes and/or scaffolds, for guided tissue (GTR) and bone regeneration (GBR) to aid in the reestablishment of the health and function of distinct periodontal tissues. This chapter offers an update on the evolution of biomaterials (i....
Operative Dentistry, 2009
Objectives: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutraliza... more Objectives: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutralization and fatigue load cycling performed on human premolars restored with ceramic inlays had an influence on microtensile bond strength results (MTBS). Methods: MOD inlay preparations were performed in 40 premolars (with their roots embedded in acrylic resin). Forty ceramic restorations were prepared using glass-ceramic (IPS Empress). The inner surfaces of all the restorations were etched with 10% hydrofluoric acid for 60 seconds, rinsed with water and dried.
Revista Brasileira de Otorrinolaringologia
As vestibulopatias atribuídas aos distúrbios do metabolismo do açúcar são ainda hoje um tema cont... more As vestibulopatias atribuídas aos distúrbios do metabolismo do açúcar são ainda hoje um tema controverso na literatura pela falta de demonstração objetiva que relacione causa e efeito. OBJETIVO: Nosso objetivo é relatar os resultados seriados do Teste de Integração Sensorial no acompanhamento dos pacientes portadores de DMA tratados com dieta fracionada e restrição de glicose. FORMA DE ESTUDO: Retrospectivo, inclui um desenho de descrição de casos. MÉTODO: Foram avaliadas as respostas de 21 pacientes portadores de distúrbios do metabolismo do açúcar e tontura submetidos à dieta fracionada com restrição de glicose. A medição objetiva do equilíbrio corporal dos pacientes foi feita pela Posturografia Dinâmica Computadorizada, utilizando-se o protocolo do Teste de Integração Sensorial. RESULTADOS: Após a instituição da dieta, observou-se melhora objetiva significante nas condições que retratam a função vestibular e o equilíbrio corporal dos indivíduos estudados. CONCLUSÃO: Concluímos qu...
Dental Materials, 2015
to evaluate the influence of the occlusal resin cement thickness on the cyclic loads-to-failure o... more to evaluate the influence of the occlusal resin cement thickness on the cyclic loads-to-failure of feldspathic crowns and to compare the results to data from monotonic tests. A large range of cement thickness (50μm and 500μm) was tested, in order to better measure the influence of this variable. Feldspathic ceramic crowns (Vita Mark II blocks, Vita Zahnfabrik) were bonded to dentin analog dies (G10 (NEMA grade G10, International Paper), with occlusal resin cement thicknesses of 50μm and 500μm (Multilink Automix, Ivoclar). The dies were prepared with microchannels for water transport to the cement layer. After 96-h water storage, the specimens (n=20) were submitted to cyclic loads (500,000 cycles at 20Hz; initial maximum load=40% of monotonic load, from previous data) following a staircase sensitivity design (step size=25N). Failure loads at 500,000 cycles were compared to monotonic failure loads (from a previous study with specimens produced by the same author, using the same materials, specimen configuration and cementation protocol). Crowns with an occlusal cement layer of 50μm were more resistant than those cemented with 500μm (246.4±22.9N vs. 158.9±22.9N), under wet cyclic testing conditions (p<0.001). The fatigue failure loads were reduced compared to monotonic loads: to 37% of monotonic for 50μm; to 53% of monotonic for 500μm. An occlusal cement thickness of 50μm was more favorable for the structural performance of feldspathic crowns than was 500μm. Cyclic fatigue reduced failure loads well below those found under monotonic loading.
Journal of biomedical materials research. Part B, Applied biomaterials, Jan 7, 2015
Composite fibrous electrospun membranes based on poly(dl-lactide) (PLA) and poly(ε-caprolactone) ... more Composite fibrous electrospun membranes based on poly(dl-lactide) (PLA) and poly(ε-caprolactone) (PCL) were engineered to include borate bioactive glass (BBG) for the potential purposes of guided bone regeneration (GBR). The fibers were characterized using scanning and transmission electron microscopies, which respectively confirmed the submicron fibrous arrangement of the membranes and the successful incorporation of BBG particles. Selected mechanical properties of the membranes were evaluated using the suture pullout test. The addition of BBG at 10 wt % led to similar stiffness, but more importantly, it led to a significantly stronger (2.37 ± 0.51 N mm) membrane when compared with the commercially available Epiguide® (1.06 ± 0.24 N mm) under hydrated conditions. Stability (shrinkage) was determined after incubation in a phosphate buffer solution from 24 h up to 9 days. The dimensional stability of the PLA:PCL-based membranes with or without BBG incorporation (10.07-16.08%) was sim...
Dental Materials, 2015
To evaluate the effects of hard machining, glaze firing and hydrofluoric acid etching on the biax... more To evaluate the effects of hard machining, glaze firing and hydrofluoric acid etching on the biaxial flexural strength and roughness of a CAD/CAM leucite glass-ceramic; to investigate if ceramic post-machining surface roughness is influenced by the machining order and by the pair of burs used for it. A hundred forty four discs were machined by six nominally identical pairs of burs and divided into groups (n=24): (1) machining-M, (2) machining and glaze firing-MG, (3) machining and hydrofluoric acid etching-MA, (4) machining, glaze firing and hydrofluoric acid etching-MGA, (5) machining followed by polishing, as a control-MP, (6) machining, polishing and hydrofluoric acid etching-MPA. The roughness after each treatment (Ra and Rz) was measured. The discs were submitted to a piston-on-three ball flexure test (ISO 6872/2008) and strength data analyzed through Weibull statistics (95% CI). M resulted in lower characteristic strength (σ0) (128.2MPa) than MP (177.2MPa). The glaze firing reduced σ0 (109MPa), without affecting roughness. Hydrofluoric acid etching increased the roughness without affecting σ0. Spearman's coefficient (rs) indicated strong and significant correlation between machining order and roughness (rsRa=-0.66; rsRz=-0.73). The ceramic post-machining surface roughness differed significantly according to the pair of burs employed (p<0.05). hard machining and glaze firing reduced the leucite ceramic strength, while hydrofluoric acid etching did not affect the strength. Variability in the roughness might be expected after machining, since it was influenced by the machining order and by the bur pairing.
Journal of endodontics, Jan 24, 2015
Actinomyces naeslundii has been recovered from traumatized permanent teeth diagnosed with necroti... more Actinomyces naeslundii has been recovered from traumatized permanent teeth diagnosed with necrotic pulps. In this work, a triple antibiotic paste (TAP)-mimic scaffold is proposed as a drug-delivery strategy to eliminate A. naeslundii dentin biofilm. Metronidazole, ciprofloxacin, and minocycline were added to a polydioxanone (PDS) polymer solution and spun into fibrous scaffolds. Fiber morphology, mechanical properties, and drug release were investigated by using scanning electron microscopy, microtensile testing, and high-performance liquid chromatography, respectively. Human dentin specimens (4 × 4 × 1 mm(3), n = 4/group) were inoculated with A. naeslundii (ATCC 43146) for 7 days for biofilm formation. The infected dentin specimens were exposed to TAP-mimic scaffolds, TAP solution (positive control), and pure PDS (drug-free scaffold). Dentin infected (7-day biofilm) specimens were used for comparison (negative control). Confocal laser scanning microscopy was done to determine bacte...
Brazilian journal of otorhinolaryngology