Shahrokh Abdi - Academia.edu (original) (raw)
Related Authors
Uploads
Papers by Shahrokh Abdi
Estimation of missing annual discharge
2010 International Conference on Environmental Engineering and Applications, 2010
... KN.Toosi University of Technology Karaj, Iran hedayati m 1 098@yahoo.comMohamad Reza Kavianpo... more ... KN.Toosi University of Technology Karaj, Iran hedayati m 1 098@yahoo.comMohamad Reza Kavianpour Associate Professor Civil and Structural Mng KN.Toosi University of Technology Tehran, Iran kavianpour@kntu.ac.ir ...
KSCE Journal of Civil Engineering, 2020
Vertical mass isolation (VMI) method is used for the seismic control of structures. In this metho... more Vertical mass isolation (VMI) method is used for the seismic control of structures. In this method, the entire structure is considered to be a combination of two mass and stiffness subsystems with an isolator layer located in-between. A magnetorheological (MR) damper is used as the isolator layer to control the structure. The semi-active control technique is applied to control the MR damper based on the applied controlling voltage. Several single degree of freedom structures with the same masses and main periods of 0.5, 1.0, 2.0 and 3.0 seconds are studied. Finally, a comparison between the results of this method with three passive control methods was performed. Results indicated that the semi-active control method based on maximum voltage of 9V will reduce, on average, the maximum roof displacement by 25% and 51% more than the Copt and passive-off methods and is equal to the passive-on method at 9V. However, the efficiency of the semi-active method in controlling the maximum absolute acceleration of the roof and the base shear of the structure was on average 28% and 45% lower than the Copt and passive-off methods, respectively and 2% higher than the passive-on method.
Estimation of missing annual discharge
2010 International Conference on Environmental Engineering and Applications, 2010
... KN.Toosi University of Technology Karaj, Iran hedayati m 1 098@yahoo.comMohamad Reza Kavianpo... more ... KN.Toosi University of Technology Karaj, Iran hedayati m 1 098@yahoo.comMohamad Reza Kavianpour Associate Professor Civil and Structural Mng KN.Toosi University of Technology Tehran, Iran kavianpour@kntu.ac.ir ...
KSCE Journal of Civil Engineering, 2020
Vertical mass isolation (VMI) method is used for the seismic control of structures. In this metho... more Vertical mass isolation (VMI) method is used for the seismic control of structures. In this method, the entire structure is considered to be a combination of two mass and stiffness subsystems with an isolator layer located in-between. A magnetorheological (MR) damper is used as the isolator layer to control the structure. The semi-active control technique is applied to control the MR damper based on the applied controlling voltage. Several single degree of freedom structures with the same masses and main periods of 0.5, 1.0, 2.0 and 3.0 seconds are studied. Finally, a comparison between the results of this method with three passive control methods was performed. Results indicated that the semi-active control method based on maximum voltage of 9V will reduce, on average, the maximum roof displacement by 25% and 51% more than the Copt and passive-off methods and is equal to the passive-on method at 9V. However, the efficiency of the semi-active method in controlling the maximum absolute acceleration of the roof and the base shear of the structure was on average 28% and 45% lower than the Copt and passive-off methods, respectively and 2% higher than the passive-on method.