Shane Smith - Academia.edu (original) (raw)

Shane Smith

Related Authors

Johannes Zachhuber

Muqtedar Khan

Armando Salvatore

Remo Caponi

Roe Fremstedal

Giulia Sissa

Jose-Manuel Barreto

Noe Cornago

Noe Cornago

University of the Basque Country, Euskal Herriko Unibertsitatea

Jack Reynolds

Elliot Wolfson

Uploads

Papers by Shane Smith

Research paper thumbnail of The first generation prototype of a surgical PET imaging probe system

IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2010

Abstract Our ultimate goal is to provide continuously updated 3-dimensional reconstructed PET ima... more Abstract Our ultimate goal is to provide continuously updated 3-dimensional reconstructed PET images during surgery that are re-projected in real time onto a plane whose orientation is driven by a tracking device. The intra-operative PET imaging probe system can be ...

Research paper thumbnail of Ax-Pet, a Demonstrator for Pet Imaging Using Long Axially Oriented Scintillating Crystals

Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications - Proceedings of the 11th Conference, 2010

Two PET scanner modules have been built in order to demonstrate the AX-PET concept in a phantom t... more Two PET scanner modules have been built in order to demonstrate the AX-PET concept in a phantom test. Each module comprises 6 layers of 8 LYSO crystals (3x3x100) mm3 orthogonally interleaved with layers of 26 wave length shifting strips (WLS) with dimensions (0.9x3x40) mm 3. The spatial resolution is defined by the dimensions of the crystals and WLS strips, while the sensitivity depends on the number of crystal layers. According to MC simulations, the sensitivity will be increased further by reconstructing Compton interactions. Crystals and WLS strips are read out by MPPCs. First module tests yield an energy resolution of the LYSO crystals of 12.33 % and 12.46 % FWHM and a spatial resolution of the WLS strips of (1.68±0.25) mm FWHM. Special simulation and reconstruction software were developed for the AX-PET demonstrator.

Research paper thumbnail of Fractured Response

Responding to Catastrophic Events, 2013

Research paper thumbnail of The first generation prototype of a surgical PET imaging probe system

IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2010

Abstract Our ultimate goal is to provide continuously updated 3-dimensional reconstructed PET ima... more Abstract Our ultimate goal is to provide continuously updated 3-dimensional reconstructed PET images during surgery that are re-projected in real time onto a plane whose orientation is driven by a tracking device. The intra-operative PET imaging probe system can be ...

Research paper thumbnail of Ax-Pet, a Demonstrator for Pet Imaging Using Long Axially Oriented Scintillating Crystals

Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications - Proceedings of the 11th Conference, 2010

Two PET scanner modules have been built in order to demonstrate the AX-PET concept in a phantom t... more Two PET scanner modules have been built in order to demonstrate the AX-PET concept in a phantom test. Each module comprises 6 layers of 8 LYSO crystals (3x3x100) mm3 orthogonally interleaved with layers of 26 wave length shifting strips (WLS) with dimensions (0.9x3x40) mm 3. The spatial resolution is defined by the dimensions of the crystals and WLS strips, while the sensitivity depends on the number of crystal layers. According to MC simulations, the sensitivity will be increased further by reconstructing Compton interactions. Crystals and WLS strips are read out by MPPCs. First module tests yield an energy resolution of the LYSO crystals of 12.33 % and 12.46 % FWHM and a spatial resolution of the WLS strips of (1.68±0.25) mm FWHM. Special simulation and reconstruction software were developed for the AX-PET demonstrator.

Research paper thumbnail of Fractured Response

Responding to Catastrophic Events, 2013

Log In