Shane Smith - Academia.edu (original) (raw)
Related Authors
University of the Basque Country, Euskal Herriko Unibertsitatea
Uploads
Papers by Shane Smith
IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2010
Abstract Our ultimate goal is to provide continuously updated 3-dimensional reconstructed PET ima... more Abstract Our ultimate goal is to provide continuously updated 3-dimensional reconstructed PET images during surgery that are re-projected in real time onto a plane whose orientation is driven by a tracking device. The intra-operative PET imaging probe system can be ...
Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications - Proceedings of the 11th Conference, 2010
Two PET scanner modules have been built in order to demonstrate the AX-PET concept in a phantom t... more Two PET scanner modules have been built in order to demonstrate the AX-PET concept in a phantom test. Each module comprises 6 layers of 8 LYSO crystals (3x3x100) mm3 orthogonally interleaved with layers of 26 wave length shifting strips (WLS) with dimensions (0.9x3x40) mm 3. The spatial resolution is defined by the dimensions of the crystals and WLS strips, while the sensitivity depends on the number of crystal layers. According to MC simulations, the sensitivity will be increased further by reconstructing Compton interactions. Crystals and WLS strips are read out by MPPCs. First module tests yield an energy resolution of the LYSO crystals of 12.33 % and 12.46 % FWHM and a spatial resolution of the WLS strips of (1.68±0.25) mm FWHM. Special simulation and reconstruction software were developed for the AX-PET demonstrator.
Responding to Catastrophic Events, 2013
IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2010
Abstract Our ultimate goal is to provide continuously updated 3-dimensional reconstructed PET ima... more Abstract Our ultimate goal is to provide continuously updated 3-dimensional reconstructed PET images during surgery that are re-projected in real time onto a plane whose orientation is driven by a tracking device. The intra-operative PET imaging probe system can be ...
Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications - Proceedings of the 11th Conference, 2010
Two PET scanner modules have been built in order to demonstrate the AX-PET concept in a phantom t... more Two PET scanner modules have been built in order to demonstrate the AX-PET concept in a phantom test. Each module comprises 6 layers of 8 LYSO crystals (3x3x100) mm3 orthogonally interleaved with layers of 26 wave length shifting strips (WLS) with dimensions (0.9x3x40) mm 3. The spatial resolution is defined by the dimensions of the crystals and WLS strips, while the sensitivity depends on the number of crystal layers. According to MC simulations, the sensitivity will be increased further by reconstructing Compton interactions. Crystals and WLS strips are read out by MPPCs. First module tests yield an energy resolution of the LYSO crystals of 12.33 % and 12.46 % FWHM and a spatial resolution of the WLS strips of (1.68±0.25) mm FWHM. Special simulation and reconstruction software were developed for the AX-PET demonstrator.
Responding to Catastrophic Events, 2013