A parametric study and a guide chart to avoid condensation-induced water hammer in a horizontal pipe (original) (raw)

Experimental Investigation of Slugging as Initiating Water Hammer Phenomenon through Indirect Contact Steam Condensing in a Horizontal Pipe Heat Exchanger

Purnomo Purnomo, SE, MM

International Journal of Technology, 2015

View PDFchevron_right

Numerical simulation of condensation induced water hammer

Vladimir Stevanovic

FME Transactions, 2008

View PDFchevron_right

Initiation of Water Hammer in a Steam/Water Pipe with a Non-Condensable Gas

Jiann Lin Chen

2000

View PDFchevron_right

Influence of variation of pipe diameter on pressure drop predictions of the new modified three-fluid model inside condensing vertical pipes

Nemat Dalir

Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering 230(1), DOI: 10.1177/0954408914538784, 2016

View PDFchevron_right

Calculation of pressure drop inside condensing vertical pipes in new inlet pressures using a new modified three-fluid model

Nemat Dalir

Scientia Iranica B, 20(3), 477–482, 2013

View PDFchevron_right

Numerical Study of Induced Condensation upon Mixing Flows of Water-stream Flow in a Tee-Junction Pipe

khaled yousef

ERJ. Engineering Research Journal

View PDFchevron_right

Experimental Study of Steam–Water Direct Contact Condensation in a Horizontal Pipe Geometry

Shumail Hassan

ICAME-22

View PDFchevron_right

Effect of steam condensation on countercurrent flow limiting in nearly horizontal two-phase flow

Seonoh YU

Nuclear Engineering and Design, 2000

View PDFchevron_right

Experimental and numerical investigations on the direct contact condensation phenomenon in horizontal flow channels and its implications in nuclear safety

Darius Laurinavičius

Kerntechnik, 2016

View PDFchevron_right

NUMERICAL CHARACTERISATION OF SLUG FLOW IN HORIZONTAL AIR/WATER PIPE FLOW

Zahid I. Al-Hashimy, HUSSAIN H AL-KAYIEM

2016

View PDFchevron_right

Modelling of Direct Contact Condensation in Horizontally Stratified Flow with CFX Code

Boštjan Končar

Benchmarking of CFD codes for application …, 2006

View PDFchevron_right

Heat transfer and flow pattern in co-current downward steam condensation in vertical pipes-I: CFD simulation and experimental measurements

Vijayan Pallippattu

The Canadian Journal of Chemical Engineering, 2012

View PDFchevron_right

An investigation of steam–water countercurrent flow model in TRACE

Chunkuan Shih

Annals of Nuclear Energy, 2010

View PDFchevron_right

Numerical investigation of temperature effect on water hammer with cavitation in copper pipe rig

Fawaz MASSOUH

2021

View PDFchevron_right

Some aspects of physical and numerical modeling of water hammer in pipelines

Faig Naghiyev

Nonlinear Dynamics, 2009

View PDFchevron_right

Numerical Simulation of the Transient Development of Slug Flow in Horizontal Pipes

Zahid I. Al-Hashimy, HUSSAIN H AL-KAYIEM

View PDFchevron_right

Experimental and theoretical study of steam condensation induced water hammer phenomena

Imre Barna

Nuclear Engineering and Design, 2010

View PDFchevron_right

CFD Study of Two-Phase Slug Flow Development in Horizontal Pipe

Celso Murilo dos Santos

Anais do SIMPROC, 2020

View PDFchevron_right

A one dimensional model for the prediction of stratification in horizontal pipes subjected to fluid temperature transient at inlet

Reuven Amar

Nuclear Engineering and Design, 1988

View PDFchevron_right

Experimental Study of Water Hammer Pressure in a Commercial Pipe

Ahmed Sami

View PDFchevron_right

Numerical analysis for slugging of steam-water stratified two-phase flow in horizontal duct

Mohammad Ozair Ansari

Fluid Dynamics Research, 1998

View PDFchevron_right

Theoretical and Experimental Study of Steam Condensation Induced Water Hammer Phenomena

Imre Barna

2008

View PDFchevron_right

Analysis for Water Hammer considering the effect of Fluid Structure Interaction in Straight Pipes

Suyash Mishra

2012

View PDFchevron_right

Internal Condensing Flows inside a Vertical Pipe: Experimental/Computational Investigations of Effects of Constrained and Natural Exit Conditions

Jorge Kurita

Heat Transfer, Part B, 2005

View PDFchevron_right

Comparative Analysis of Water-Hammer Calculation by the Approximate and the Complete Methods of Characteristics

Roman Wichowski

Periodica Polytechnica Civil Engineering, 1991

View PDFchevron_right

Internal Condensing Flows inside a Vertical Pipe: Experimental/Computational Investigations of the Effects of Specified and Unspecified (Free) Conditions at Exit

Jorge Kurita

Journal of Heat Transfer, 2007

View PDFchevron_right

Influence of Tube Diameter and Steam Flow Rate on Heat Transfer in a Vertical Pipe of Condenser: Experimental Investigation of Copper Pipes

Filip Toman

Chemical engineering transactions, 2021

View PDFchevron_right

Comparison of water vapour condensation in vertically oriented pipes of condensers with internal and external heat rejection

Filip Toman

Energy, 2020

View PDFchevron_right

A Study of Steam-Water Countercurrent Flow Model in TRACE Code

Chunkuan Shih

Volume 3: Thermal Hydraulics; Current Advanced Reactors: Plant Design, Construction, Workforce and Public Acceptance, 2009

View PDFchevron_right

A simple approach to the prediction of waterhammer transients in a pipe line with entrapped air

michael epstein

Nuclear Engineering and Design, 2008

View PDFchevron_right

Engineering computation method for the high-velocity flow and condensation of saturated steam in a cold pipeline

V. Nakoryakov

Journal of Engineering Thermophysics, 2008

View PDFchevron_right

Condensation induced non-condensables accumulation in a non-vented vertical pipe

Vladimir Stevanovic

International journal of heat and mass …, 2005

View PDFchevron_right