Cardiac Catheterization Research Papers - Academia.edu (original) (raw)

1,364 Followers

Recent papers in Cardiac Catheterization

A remote magnetic navigation system (MNS) is available and has been used with a 4-mm-tip magnetic catheter for radiofrequency (RF) ablation of some supraventricular and ventricular arrhythmias; however, it has not been evaluated for the... more

A remote magnetic navigation system (MNS) is available and has been used with a 4-mm-tip magnetic catheter for radiofrequency (RF) ablation of some supraventricular and ventricular arrhythmias; however, it has not been evaluated for the ablation of cavotricuspid isthmus-dependent right atrial flutter (AFL). The present study evaluates the feasibility and efficiency of this system and the newly available 8-mm-tip magnetic catheter to perform RF ablation in patients with AFL. Twenty-six consecutive patients (23 men, mean age 64.6 +/- 9.6 years) underwent RF ablation using a remote MNS. RF ablation was performed with an 8-mm-tip magnetic catheter (70 degrees C, maximum power 70 W, 90 seconds). The endpoint of ablation was complete bidirectional isthmus block. To assess a possible learning curve, procedural data were compared between the first 14 (group 1) and the rest (group 2) of the patients. The initial rhythm during ablation was AFL in 20 (19 counterclockwise and 1 clockwise) and s...

Ventricular septal defect (VSD) is a life-threatening complication of transmural myocardial infarction. Urgent surgical repair and concomitant revascularization are the standard of care. Percutaneous catheter-based closure techniques have... more

Ventricular septal defect (VSD) is a life-threatening complication of transmural myocardial infarction. Urgent surgical repair and concomitant revascularization are the standard of care. Percutaneous catheter-based closure techniques have been reserved for patients with a high-risk surgery or a failed surgical procedure with residual shunting. This case report demonstrates the successful transcatheter closure of residual VSD using the Amplatzer muscular VSD device (Amplatzer, Minnesota, USA) after surgical patch dehiscence for postinfarction VSD and 3-and-a-half years' post-intervention follow-up.

Femoral artery pseudoaneurysm is a significant complication in patients undergoing diagnostic or therapeutic catheterisation. First choice treatment for pseudoaneurysm is freehand ultrasound guided compression repair, which is time... more

Femoral artery pseudoaneurysm is a significant complication in patients undergoing diagnostic or therapeutic catheterisation. First choice treatment for pseudoaneurysm is freehand ultrasound guided compression repair, which is time consuming and uncomfortable for the patient and operator. To explore a mechanical compression device (FemoStop) as an alternative treatment for iatrogenic femoral artery pseudoaneurysm. Fourteen patients with pseudoaneurysm were considered for treatment with FemoStop after a brief freehand ultrasound guided compression repair to confirm the compressibility of the lesion. The FemoStop compression was applied for 20 minutes. The result was controlled with colour Doppler ultrasound, and a second cycle of 20 minutes followed if necessary. FemoStop compression was successful in 13 of the 14 patients. The mean compression time was 33 minutes (range, 20-60). The mean number of compression periods was 1.6 (range 1-3). FemoStop compression was successful in all 11...

In this study computer models are used for simulating electrical impedance signals from intracardiac catheter inserted to the bottom of the left ventricle of the heart. Frequency dependent models are used for tissue impedance simulation... more

In this study computer models are used for simulating electrical impedance signals from intracardiac catheter inserted to the bottom of the left ventricle of the heart. Frequency dependent models are used for tissue impedance simulation that produce complex impedance signals. 3D dynamic heart is composed of dynamic spline surfaces. Five different stroke volumes of the heart have been studied. Impedance signals from the catheter electrodes are calculated with Finite Difference Method using complex tissue impedance values at frequencies 1 kHz and 1 MHz. We were able to see clear correlation between the volume change of the left ventricle and the simulated signal. The signal magnitude change was really small -- less than 0.3 %. The phase angle of the simulated signal and its' dynamic change was more pronounced at 1 kHz frequency and had a small change but was a lot higher overall at 1Mz frequency. The correlation of phase angle with left ventricle volume change was clearer than sig...

The STS/ACC Transcatheter Valve Therapy (TVT) Registry captures all procedures with Food and Drug Administration (FDA) approved transcatheter valve devices performed in the United States and is mandated as a condition of reimbursement by... more

The STS/ACC Transcatheter Valve Therapy (TVT) Registry captures all procedures with Food and Drug Administration (FDA) approved transcatheter valve devices performed in the United States and is mandated as a condition of reimbursement by a Centers for Medicaid and Medicare Services (CMS) OBJECTIVES: This annual report focuses on patient characteristics, trends, and outcomes of transcatheter aortic and mitral valve catheter-based valve procedures in the United States. Data for all patients receiving commercially approved devices from 2012 through December 31, 2015 are entered in the TVT Registry. The 54,782 TAVR patients demonstrated decreases in expected risk of 30-day operative mortality (STS PROM) 7% to 6% and TAVR PROM (TVT PROM) 4% to 3% (both p<.0001) from 2012 to 2015. Observed in-hospital mortality decreased from 5.7% to 2.9% and one-year mortality decreased from 25.8% to 21.6. However, 30-day post procedure pacemaker insertion increased from 8.8% in 2013 to 12.0% in 2015....

Among patients undergoing coronary procedures, patients with coronary artery bypass grafts represent an important, high risk subgroup. Routine transradial approach may be successfully adopted in these patients to reduce access-site... more

Among patients undergoing coronary procedures, patients with coronary artery bypass grafts represent an important, high risk subgroup. Routine transradial approach may be successfully adopted in these patients to reduce access-site complications. However, transradial cannulation of the grafts may result technically demanding. In this article we discuss the specific technical issues and we present a series of tips and tricks which may facilitate angiography and interventions on both internal mammary and aorto-coronary grafts. © 2008 Wiley-Liss, Inc.

A 48-year-old woman presented with severe acute heart failure of 7 days duration. Because of her rapidly worsening clinical condition, anatomical diagnosis of aortopulmonary fistula was made by urgent cardiac catheterization, and she... more

A 48-year-old woman presented with severe acute heart failure of 7 days duration. Because of her rapidly worsening clinical condition, anatomical diagnosis of aortopulmonary fistula was made by urgent cardiac catheterization, and she successfully underwent immediate surgical closure. Retrospectively, the diagnosis of syphilitic aortitis complicated with aortopulmonary fistula was made by clinical profile, serology, and histopathology.

The cryoballoon catheter ablates atrial fibrillation (AF) triggers in the left atrium (LA) and pulmonary veins (PVs) via transseptal access. The typical transseptal puncture site is the fossa ovalis (FO) - the atrial septum's thinnest... more

The cryoballoon catheter ablates atrial fibrillation (AF) triggers in the left atrium (LA) and pulmonary veins (PVs) via transseptal access. The typical transseptal puncture site is the fossa ovalis (FO) - the atrial septum's thinnest section. A potentially beneficial transseptal site, for the cryoballoon, is near the inferior limbus (IL). This study examines an alternative transseptal site near the IL, which may decrease the frequency of acute iatrogenic atrial septal defect (IASD). Also, the study evaluates the acute pulmonary vein isolation (PVI) success rate utilizing the IL location. 200 patients were evaluated by retrospective chart review for acute PVI success rate with an IL transseptal site. An additional 128 IL transseptal patients were compared to 45 FO transseptal patients by performing Doppler intracardiac echocardiography (ICE) post-ablation to assess transseptal flow after removal of the transseptal sheath. After sheath removal and by Doppler ICE imaging, 42 of 12...

To assess a role of volume-to-creatinine clearance ratio (V/CrCl) and iodine dose-to-creatinine clearance ratio (I-dose/CrCl) in predicting contrast- induced nephropathy (CIN) in diabetic patients undergoing elective cardiac... more

To assess a role of volume-to-creatinine clearance ratio (V/CrCl) and iodine dose-to-creatinine clearance ratio (I-dose/CrCl) in predicting contrast- induced nephropathy (CIN) in diabetic patients undergoing elective cardiac catheterization or percutaneous coronary intervention (PCI). In diabetic patients undergoing cardiac catheterization or PCI, the incidence of CIN is higher than in non-diabetic patients. High doses of contrast media also increase the likelihood of renal dysfunction. The ratio of the volume of contrast media to creatinine clearance (V/CrCl) and iodine dose-to-creatinine clearance (I-dose/CrCl) has been shown to correlate with the area under the curve of contrast media concentration over time and was used to predict the occurrence of CIN in unselected patients. No study has been conducted specifically in diabetic patients undergoing cardiac catheterization or PCI before. We conducted a prospective, single center study. The V/CrCl and I-dose/CrCl were calculated in...

The aim of this report is to provide a standard educational structure for nurses and allied professionals (NAP) specialising in interventional cardiology. The curriculum can also be used as a basis for training on a certificate-based... more

The aim of this report is to provide a standard educational structure for nurses and allied professionals (NAP) specialising in interventional cardiology. The curriculum can also be used as a basis for training on a certificate-based level in interventional cardiology. The curriculum was developed by a panel of experts from various allied health professions. The syllabus focuses on nine core areas of themes essential for NAP working in interventional cardiology. The highly technical knowledge required for working in interventional cardiology as well as the various roles of the different professional groups have been taken into consideration. This core curriculum will ensure that essential content is covered during education and a basic level of quality is achieved across specialty cardiovascular educational programmes throughout Europe.

Log In