Electric Power Factor Correction Research Papers (original) (raw)

1 Follower

Recent papers in Electric Power Factor Correction

This paper presents the design and analysis of a new configuration of parallel connected inverter suitable for fuel cell system application. The configuration consists of dc/dc converter and parallel three-phase dc/ac inverter. Series... more

This paper presents the design and analysis of a new configuration of parallel connected inverter suitable for fuel cell system application. The configuration consists of dc/dc converter and parallel three-phase dc/ac inverter. Series resistors added to the inverter output to maintain same current in each inverter of the two parallel inverters, and to reduce the circulating current in the parallel inverters to minimum. Third harmonic injection PWM (THIPWM) reduces the total harmonic distortion and to make maximum use of the voltage source. DSP was used to create the THIPWM and the control algorithm for the converter. PID controller is applied on the full-bridge dc/dc converter side to maintain the ac voltage to the required level. Experimental results have been shown to validate the proposed system.

This paper presents the design and analysis of a new configuration of parallel connected inverter suitable for fuel cell system application. The configuration consists of dc/dc converter and parallel three-phase dc/ac inverter. Series... more

This paper presents the design and analysis of a new configuration of parallel connected inverter suitable for fuel cell system application. The configuration consists of dc/dc converter and parallel three-phase dc/ac inverter. Series resistors added to the inverter output to maintain same current in each inverter of the two parallel inverters, and to reduce the circulating current in the parallel inverters to minimum. Third harmonic injection PWM (THIPWM) reduces the total harmonic distortion and to make maximum use of the voltage source. DSP was used to create the THIPWM and the control algorithm for the converter. PID controller is applied on the full-bridge dc/dc converter side to maintain the ac voltage to the required level. Experimental results have been shown to validate the proposed system.

Detailed analysis, simulation and hardware results of grid connected inverter with maximum power point tracker and power factor control in Malaysian climate are presented. A six-switch topology inverter with symmetrical Pulse Width... more

Detailed analysis, simulation and hardware results of grid connected inverter with maximum power point tracker and power factor control in Malaysian climate are presented. A six-switch topology inverter with symmetrical Pulse Width Modulation (PWM) switching technique is used. A low pass filter is incorporated in the circuit to filter out unwanted harmonics and produce a sinusoidal AC current. Low total harmonic current distortion at the inverter output can be achieved. The three-phase PWM switching pattern was developed using Xilinx FPGA. The developed system is also capable of adjusting the power factor to unity. A 3 kVA power transformer with a 1:2 ratio is constructed to provide galvanic isolation for better circuit performance and circuit protection. Hardware results for proposed solar photovoltaic inverter configuration interconnected to the grid are also presented. From the experimental results it is confirmed that the harmonic distortion of the inverter output waveform is within the limits laid down by the utility companies.

Abstract This paper presents the design and analysis of a new configuration of parallel connected inverter suitable for distributed generation application. The configuration consists of DC/DC converter and parallel three-phase DC/AC... more

Abstract This paper presents the design and analysis of a new configuration of parallel connected inverter suitable for distributed generation application. The configuration consists of DC/DC converter and parallel three-phase DC/AC inverter. Series resistors added to the inverter output to maintain same current in each inverter of the two parallel inverters, and to reduce the circulating current in the parallel inverters to the minimum. Third harmonic injection PWM (THIPWM) reduces the total harmonic distortion and to make maximum use ...

This paper deals with the simulation and implementation of boost Converter with the need for power factor correction, the utilization of active clamping technique in the boost converter, this circuit incorporation of compound active... more

This paper deals with the simulation and implementation of boost Converter with the need for power factor correction, the utilization of active clamping technique in the boost converter, this circuit incorporation of compound active clamping boost converter, its modes of operation and analysis of step of chopper. This analysis involves the simulation analysis of the compound active clamping boost PFC converter. It gives the details about the circuit implementation. The laboratory model is implemented and the experimental results are obtained. These experimental results are correlated with the simulation results.