microscopes (original) (raw)

Definition: instruments for seeing very small objects

Categories: article belongs to category vision, displays and imaging vision, displays and imaging, article belongs to category optical metrology optical metrology

Related: microscope objectivesocular lenseslaser microscopyfluorescence microscopyloupesmagnifying glasses

Page views in 12 months: 401

DOI: 10.61835/ctx Cite the article: BibTex BibLaTex plain textHTML Link to this page! LinkedIn

Content quality and neutrality are maintained according to our editorial policy.

📦 For purchasing microscopes, use the RP Photonics Buyer's Guide — an expert-curated directory for finding all relevant suppliers, which also offers advanced purchasing assistance.

Contents

What are Microscopes?

Conventional Optical Microscopes

Basic Optical Setup; Magnification

Numerical Aperture and Resolution; Working Distance

Depth of Field

Ergonomic Viewing Direction

Microscope Standards and Tube Lengths; Finite-corrected and Infinity-corrected Objectives

Object Illumination

Holding the Specimen

Modified Imaging Methods

Image Orientation

Stereo Microscopes

Microscope Cameras

Scanning Optical Microscopes

Fluorescence Microscopes

Near Field Scanning Microscopes

Microscopes for Specific Applications

Frequently Asked Questions

Summary: This article provides a comprehensive introduction to optical microscopes. It explains the principles of conventional compound microscopes, including the roles of the objective and eyepiece, magnification, resolution, and numerical aperture. Key concepts such as depth of field, Köhler illumination, and the differences between finite-corrected and infinity-corrected objectives are detailed. Furthermore, it explores advanced techniques like phase contrast, polarization, and fluorescence microscopy, as well as the operation of scanning optical microscopes, including confocal and near-field scanning microscopes.

What are Microscopes?

Microscopes are instruments which allow one to see very small objects in fine detail. There is a wide range of different microscopes, utilizing different kinds of radiation for the imaging: in many cases visible light, in other cases infrared or ultraviolet light or even X-rays. Electron microscopes use fast electron beams, allowing for very high resolution because of their small de Broglie wavelength. Also, there are microscopes not working with radiation at all, for example scanning force microscopes, where tiny forces between a very sharp tip and a sample are exploited.

This article focuses on optical microscopes, but not only those of conventional types.

Conventional Optical Microscopes

Conventional optical microscopes work based on imaging with visible light, i.e., in the wavelength region from 400 to 700 nm.

Basic Optical Setup; Magnification

microscope setup

Figure 1: Basic optical setup of a compound microscope with objective and an eyepiece around a tube.

Some moderate degree of magnification (e.g. 20 ×) can be achieved with a loupe or a magnifying glass, which is often a single lens. That concept, however, is quite limiting; it is not practical for strong magnification.

A microscope goes far beyond that and typically involves magnification in two steps, using more than one essential optical component for image formation (compound microscope with a relay lens system). Essentially, a microscope consists of a tube, where on the object side there is a microscope objective and on the viewing side an eyepiece (ocular lens) (see Figure 1).

There is an intermediate image of the object within the instrument, generated by the objective. There can also be an additional lens in the tube (not shown in Figure 1), which together with the objective forms the intermediate image.

The overall microscope magnification can be seen as the product of the magnification of objective and eyepiece. The microscope objective contributes a magnification factor typically between 4 and 100, while the eyepiece gives another factor of 5 or 10, for example. This means that the overall magnification may be as small as 20 in some cases and 1000 in other cases.

Microscopes often contain multiple objectives on a rotatable nosepiece, for example:

The eye piece may be fixed or also exchangeable.

Note that the definition of the magnification factor in microscopy is based on a comparison of viewing angles between two situations:

A large magnification alone is not necessarily helpful if it only makes images larger without increasing the level of detail. However, the magnification should at least be large enough to allow the human eye to utilize the full image resolution provided by the objective. Therefore, microscope objectives with high numerical aperture, allowing for high resolution, generally also have a high magnification.

As a numerical example, consider the angular resolution of the human eye, which is about one arc minute (not much worse than the diffraction limit for a usual pupil diameter of a couple of millimeters). This corresponds to an object size of ≈73 μm in a viewing distance of 250 mm. A possible 1000 × magnification of a microscope might suggest that objects as small as 73 nm could be seen. However, the actual achievable image resolution is normally a few hundred nanometers, i.e., significantly worse. This shows that a 1000 × magnification goes somewhat beyond what is necessary to exploit the full image resolution, but it may nevertheless be convenient.

Numerical Aperture and Resolution; Working Distance

The image resolution is ultimately limited by the numerical aperture of the microscope objective. Essentially, this is because at least the first diffraction order of light scattered by closely spaced object points must contribute to the image to get such points resolved. Of course, a high optical quality of the objective is also essential for utilizing that resolution potential, but it has been possible for a long time already to achieve more or less diffraction-limited resolution.

There are different ways of calculating the image resolution under slightly different circumstances, but they lead to similar resolution values, which are roughly ($\lambda / (2 \: \rm{NA})$), where ($\lambda$) is the optical wavelength (about 400 to 700 nm) and NA is the numerical aperture. For example, an NA of 0.9 allows for an image resolution of roughly 300 nm with green light and somewhat better with blue light. Such high-NA objectives have a very small focal length (e.g. 2 mm) and a correspondingly small working distance.

The highest resolution, based on the highest NA values around 1.5 to 1.6, is achieved with immersion objectives, where one uses some immersion oil (a liquid with relatively high refractive index) in the narrow gap between the objective and the object. Modern synthetic immersion oils are relatively convenient to use, compared with previously used substances which had a much higher tendency to produce stains and therefore required correspondingly more frequent and intense cleaning efforts. Of course, it is still more convenient to work with a dry objective, which however has a significantly lower resolution limit.

For low magnification, an NA of 0.1 is fully sufficient. This is a typical value for a scanning lens with a magnification of e.g. 4 ×. Such objective lenses are useful for a first orientation, viewing a larger part of the specimen's area. Here, the comparatively long focal length of e.g. 40 mm allows for a substantial working distance.

Depth of Field

In any kind of optical image formation, there is a limited depth of field, i.e., a limited range of distances of objects where sharp imaging is possible. The higher the numerical aperture, the lower the depth of field. Therefore, microscope objectives with a high numerical aperture of e.g. 0.85 result in a very small depth of field of only ≈0.4 μm.

Parts of the object just before and after the focused plane also contribute to the image, but not in a well focused way. Therefore, perfect image quality is achieved when the objects are very thin. This is different, however, in scanning confocal microscopy (see below).

Ergonomic Viewing Direction

It is often useful to have the object oriented in a horizontal way, while having a viewing direction which is not vertical, but at some more convenient angle for ergonomic use in a sitting position. Therefore, the light coming from the object is usually deflected with a prism, for example.

Microscope Standards and Tube Lengths; Finite-corrected and Infinity-corrected Objectives

Obviously, the tube length is an important design parameter influencing the image formation if the objective is meant to produce an intermediate image at a finite distance. (The object is then supposed to be placed a little below the front focal plane of the objective, and the objective is designed for minimum image distortions in that configuration; it is called finite-corrected.) Therefore, such microscope objectives are always designed for a certain tube length. This has been common in older microscopes.

There are two common microscope standards, namely the DIN (Deutsche Industrie Norm) standard and the Japanese “JIS” standard; these differ in terms of tube length. According to DIN, the mechanical tube length is 160 mm, measured from the nosepiece opening, where the objective is mounted, to the top edge of the tube where the eyepiece is inserted. The optical tube length, defined as the distance between the rear focal point of the objective to the front focal point of the eyepiece, is somewhat shorter. For comparison, the “JIS” tube length is a little longer (170 mm), and others have a tube length of even 215 mm. The 160 millimeter tube length has also been standardized by the Royal Microscopical Society (RMS), but that did not stop some manufacturers from using different values, perhaps because they did not want to give up their product line of objectives.

Obviously, the rules for defining the tube length become more complicated for the common configurations with additional beam deflection between objective and eyepiece.

Microscope objectives for modern professional instruments are usually designed for infinity correction. This means that the object is supposed to be placed exactly in the front focal plane of the objective, and the generated intermediate image lies in infinite distance. It is then the task of an additional tube lens to form a real image in the intermediate image plane close to the eyepiece (at its front focal point). The advantages of using infinity-corrected objectives are essentially the following:

Due to those advantages, which became more important with increasing complexity of typical microscopic instruments, it has become standard to use infinity-corrected microscope objectives.

From a user perspective, it is not essential to understand the details e.g. how exactly the mechanical and optical tube length is measured. However, it is essential to select microscope objectives which are fully compatible with the used microscope, as indicated by the microscope standard; otherwise, the image quality may be reduced significantly from non-compensated spherical aberrations.

Object Illumination

The illumination of the object is a critical factor for the achievable image quality. Depending on the type of object, different directions of illumination can be appropriate:

Of course, it would be detrimental to image the coiled filament of a lamp to the sample; this could create an unwanted filament image. It is desirable to achieve a homogeneous illumination despite an inhomogeneous shape of the emitting object in the lamp. The primary method for high-quality microscopes is Köhler illumination, where several optical elements such as a field diaphragm and a condenser are employed. The arrangement is made such that there are two well separated sets of conjugate planes (interlaced beam path): an image-forming plane set (with specimen, intermediate image plane and the eye's retina) and an illumination plane set with lamp filament, condenser diaphragm, objective real focal plane and eye iris. Köhler illumination allows one to exploit the full resolution potential of the microscope objective without losing much of the light. Alternative solutions, based on optical diffusers, lead to higher light losses.

While some microscopes are specialized to one particular illumination method, others are quite versatile, giving the user the choice between transmission and reflection mode, for example.

The used light source is often a tungsten–halogen lamp, producing bright white light. Due to the rather low efficiency of light generation and delivery, the lamp housing can become rather hot. Recently, light-emitting diodes (LEDs) have also been used for microscope illumination systems.

With a movable mirror in the microscope, one may switch between illumination from the top or from the bottom.

Holding the Specimen

The object under investigation must be properly fixed and positioned below the microscope objective. In most cases, the specimen is held in a horizontal position, with viewing from the top (in z direction). In biology, for example, the specimen is typically placed on a microscope slide and covered with a 0.17 mm thick cover slip (cover glass), which rests on it without further measures or is fixed with some clips or clamps. The spherical aberrations caused by the cover slip need to be compensated by the objective for large NA values (e.g. >0.75 for dry objectives, >1 for immersion objectives). Some microscopes have an additional knob for adjusting that compensation when e.g. a plate of non-standard thickness is used. Of course, solid samples generally do not need a cover slip and therefore also not the corresponding compensation.

There are also inverted microscopes, where the illumination is from the top and viewing from the bottom, of course with a deflection applied for obtaining a convenient viewing angle. The essential advantage of inverted microscopes is to leave substantial working space above the specimen: the illuminator does not merely have to be as close to the specimen as an objective for high resolution.

Ideally, there are high-quality opto-mechanics for precisely translating the sample in x, y and z direction. Particularly for high magnification, the depth of field is rather low, so that precise positioning also in z direction is important. In many cases, however, it is sufficient to move the optical setup up and down with a large knob, offering limited precision.

Modified Imaging Methods

Imaging formation is often based on a variable absorbance or transmittance of the sample, or on light scattered from features of the object. However, there are modified techniques for getting image contrast:

Such methods can reveal structures in objects which can hardly be seen with other methods.

Another possibility for improving the visibility of structures is to use staining with certain dyes, which preferentially attach to certain parts of samples — for example, to organelles within biological cells. That increases the efforts of sample preparation, but can lead to substantially improved images.

Image Orientation

Simple microscopes produce inverted images. This is not a problem for many applications, but inconvenient e.g. in cases where samples need to be manipulated under a microscope. Therefore, some microscopes contain additional optical elements for obtaining non-inverted images.

Stereo Microscopes

While many microscopes have only a single eyepiece, there are also binocular microscopes with two eyepieces and one or two objectives. The two observing eyes obtain images from slightly different directions, allowing for stereoscopic vision with a three-dimensional impression.

The requirement of dual optics is of course a major limiting factor. Such microscopes are usually used only for viewing in reflection with moderate magnification — roughly an order of magnitude lower than for conventional microscopes. For some stereo microscopes, objectives cannot easily be exchanged. However, they may have a zoom function, i.e., they allow an adjustment of the magnification within some range.

Microscope Cameras

Most microscopes are equipped with an eyepiece for direct viewing. However, there are also microscopes with a camera, producing either photographs or video images; devices with digital cameras, as have become dominant, are also called digital microscopes. It is also possible to have an eyepiece plus a camera for use at the same time, or for switching between both modes. There are also camera adapters which can be inserted instead of eyepieces; they may contain additional optics for adjusting the image size and resolution.

While early microscope cameras used a photographic film, modern devices are based on an electronic image sensor and are typically connected to a computer, e.g. with a USB cable. A large computer screen may actually be very convenient for inspecting images, providing easy viewing even for more than one person. Images or videos can conveniently be recorded for later inspection. Further, one may apply computational techniques for image improvement.

Scanning Optical Microscopes

Conventional optical microscopes as explained above provide a complete image at any moment. Some modified techniques are used in scanning optical microscopes, where only the information on a single image point is provided at a time, and a complete two-dimensional or three-dimensional image is built up (typically in a computer) by systematically moving the sample and/or an imaging beam into up to three dimensions.

confocal microscope

Figure 2: Setup of a confocal laser microscope.

An example is a confocal scanning laser microscope (Figure 2), where a diffraction-limited collimated laser beam is tightly focused onto the sample. The light coming back from the focus point (e.g. through scattering in the sample) is imaged onto a small pinhole and transmitted to a photodetector. Light coming from other longitudinal or transverse positions in the sample is largely suppressed:

For operation in transmission, laser illumination may be done through a second microscope objective on the other side of the sample.

Fluorescence Microscopes

The confocal operation principle is also often used in fluorescence microscopes. Here, one does not detect scattered laser light, but rather fluorescence light. The laser light itself may be suppressed by an optical filter.

See the article on fluorescence microscopy for more details. It explains, for example, how sub-diffraction resolution (super-resolution) can be achieved with certain techniques.

Near Field Scanning Microscopes

Near field scanning microscopes (NSOMs) have been developed which can produce an image resolution beyond the diffraction limit. Here, one uses a very tiny fiber tip for scanning the surface of a sample. The very small distance between the tip and the sample is stabilized with a suitable feedback mechanism, usually using contact forces.

There are different operation modes of such microscopes:

One may apply additional techniques for obtaining contrast, for example involving polarization, phase contrast, differential interference contrast or staining.

Microscopes for Specific Applications

Microscopes are often optimized for certain typical applications. Some examples:

Frequently Asked Questions

What is an optical microscope?

An optical microscope is an instrument that uses visible light and a system of lenses to create magnified images of very small objects. A compound microscope typically uses a microscope objective to form an intermediate image, which is then further magnified by an eyepiece.

What is the difference between magnification and resolution in microscopy?

Magnification is the extent to which an object appears larger through the microscope. Resolution is the ability to distinguish fine details, i.e., to see closely spaced points as separate. High magnification without sufficient resolution only produces a larger, blurry image.

What limits the resolution of an optical microscope?

The image resolution is fundamentally limited by the diffraction of light. It depends on the numerical aperture (NA) of the objective and the wavelength of the light used for imaging. A higher NA and shorter wavelength result in better resolution.

What are infinity-corrected microscope objectives?

Infinity-corrected objectives are designed so that an object in the front focal plane produces parallel light rays. A separate tube lens then forms the intermediate image. This design allows for adding optical elements like beam splitters into the parallel beam path without degrading image quality.

What is Köhler illumination?

Köhler illumination is an advanced method for sample illumination in high-quality microscopes. It uses a condenser and diaphragms to achieve very homogeneous illumination, which allows for exploiting the full resolution potential of the objective.

What is a confocal scanning microscope?

A confocal scanning microscope builds an image point by point. It uses a focused laser beam to illuminate a tiny spot on the sample and a pinhole in the detection path to block light from out-of-focus planes, resulting in sharp, high-contrast images with excellent depth discrimination.

Why is immersion oil used with some microscope objectives?

Immersion oil, which has a high refractive index, is placed between the objective and the sample. This increases the light-gathering angle and thus the numerical aperture (NA) of the objective beyond what is possible in air, leading to a significantly higher image resolution.

How does fluorescence microscopy work?

In fluorescence microscopy, the sample is illuminated with light of a certain wavelength to excite fluorescence. The microscope then detects the emitted fluorescence light, which has a longer wavelength, often using an optical filter to block the excitation light. This allows for imaging specific labeled structures.

What is the difference between bright-field and dark-field microscopy?

In bright-field microscopy, the specimen is illuminated directly along the optical axis, appearing as a dark object on a bright background. In dark-field microscopy, the specimen is illuminated from the side, so only scattered light enters the objective, making the object appear bright against a dark background.

Suppliers

Sponsored content: The RP Photonics Buyer's Guide contains 46 suppliers for microscopes. Among them:

Edmund Optics

⚙ hardware

microscopes

Edmund Optics offers stereo microscopes by industry leading manufacturers, including Mitutoyo and Olympus. The Mitutoyo FS70 inspection microscope is compatible with the Mitutoyo infinity corrected objectives. The Olympus stereo microscopes offer various mounting configurations for a variety of application and system spaces. Edmund Optics also offers a variety of stereo microscope accessories, including cameras or vibration isolation tables which minimize vibrations from interfering with image quality.

Questions and Comments from Users

Here you can submit questions and comments. As far as they get accepted by the author, they will appear above this paragraph together with the author’s answer. The author will decide on acceptance based on certain criteria. Essentially, the issue must be of sufficiently broad interest.

Please do not enter personal data here. (See also our privacy declaration.) If you wish to receive personal feedback or consultancy from the author, please contact him, e.g. via e-mail.

By submitting the information, you give your consent to the potential publication of your inputs on our website according to our rules. (If you later retract your consent, we will delete those inputs.) As your inputs are first reviewed by the author, they may be published with some delay.