Related: focuswavefrontslaser beam characterizationdiffraction-limited beamsGaussian beams_M_^2 factorbeam radiusbeam divergencebeam parameter productbrightnessbeam profilersthermal lensingThe Ideal Pump Intensity Distribution in an End-Pumped Solid-State LaserBeam Quality Measurements Can Easily Go WrongWhat is a High Laser Beam Quality?

Page views in 12 months: 5330

DOI: 10.61835/8mq Cite the article: BibTex BibLaTex plain textHTML Link to this page! LinkedIn

Content quality and neutrality are maintained according to our editorial policy.

📦 For purchasing beam quality, use the RP Photonics Buyer's Guide — an expert-curated directory for finding all relevant suppliers, which also offers advanced purchasing assistance.

Contents

Definition of Beam Quality

The beam quality of a laser beam is an important aspect of laser beam characterization. It can be defined in different ways, but is normally understood as a measure of how tightly a laser beam can be focused under certain conditions (e.g. with a limited beam divergence). The most common ways to quantify the beam quality are:

Low values of BPP or ($M^2$) factor imply a high beam quality.

A high beam quality implies smooth wavefronts (i.e., strong phase correlation across the beam profile), such that focusing the beam with a lens allows one to obtain a focus where the wavefronts are plane. Scrambled wavefronts (see Figure 1) make beam focusing more difficult, i.e., the beam divergence for a given spot size is increased.

laser beam with poor beam quality

Figure 1: A laser beam with poor beam quality. In contrast to an ideal Gaussian beam, the wavefronts are somewhat scrambled, which makes it more difficult to tightly focus the beam.

The highest possible beam quality in terms of ($M^2$) is achieved for a diffraction-limited Gaussian beam, having ($M^2 = 1$). That value is closely approached by many lasers, in particular by solid-state bulk lasers operating on a single transverse mode (→ single-mode operation) and by fiber lasers based on single-mode fibers, also by some low-power laser diodes (particularly VCSELs). On the other hand, in particular some high-power lasers (e.g. solid-state bulk lasers and semiconductor lasers such as diode bars) can have a very large ($M^2$) of more than 100 or even well above 1000. In solid-state lasers, this is often a result of thermally induced wavefront distortions in the gain medium and/or a mismatch of effective mode area and pumped area in the laser crystal, whereas in high-power semiconductor lasers the poor beam quality results from operation with a highly multimode waveguide. In both cases, the poor beam quality is associated with the excitation of higher-order resonator modes.

In the focus (beam waist) of a diffraction-limited beam (i.e., at the location where the beam radius reaches its minimum), the optical wavefronts are flat. Any scrambling of the wavefronts, e.g. due to optical components with poor quality, spherical aberrations of lenses, thermal effects in a gain medium, diffraction at apertures, or by parasitic reflections, can spoil the beam quality. For monochromatic beams, the beam quality could in principle be restored e.g. with a phase mask which exactly compensates the wavefront distortions, but this is usually difficult in practice, even in cases where the distortions are stationary. A more flexible approach is to use adaptive optics in combination with a wavefront sensor.

It is possible to some extent to improve the beam quality of a laser beam with a non-resonant mode cleaner or a mode cleaner cavity. This, however, leads to some loss of optical power.

The brightness of a laser, or more precisely its radiance, is determined by its output power together with its beam quality.

Note that the term beam quality is sometimes used with a qualitative meaning which has little to do with the focusability as discussed above. For some applications, it is vital to obtain a smooth beam intensity profile, e.g. of Gaussian shape, whereas the beam divergence is not of interest. The “quality” of a laser beam may then not be characterized e.g. with an ($M^2$) as discussed below: one beam may have a relatively small ($M^2$) value but a multi-peaked beam profile, whereas another beam may have a smooth beam shape but a high divergence and thus a large ($M^2$) value.

Some laser applications such as lithography require the uniform illumination of a large area. If the term beam quality appears in that context, it may have nothing to do with focusability as discussed in this article. One may then even prefer beams with a rather low spatial and temporal coherence.

Measurement of Beam Quality

According to ISO Standard 11146, the beam quality factor ($M^2$) can be calculated with a fitting procedure, applied to the measured evolution of the beam radius along the propagation direction (the so-called caustic, see Figure 2). For correct results, a number of rules have to be observed, e.g. concerning the exact definition of the beam radius and the placing of data points.

beam quality calculation from measured caustic

Figure 2: Calculation of the beam quality from the measured caustic.

The black data points are those used for the fitting procedure, whereas the gray points are ignored. (A balanced selection of data points, with some near the beam waist and others at a sufficient distance from it, is required according to ISO Standard 11146.)

There are commercially available beam profilers which can automatically perform beam quality measurements within a few seconds. They are normally based on the measurement of the beam profile at different positions. Beam profilers based on different measurement principles, e.g. CCD and CMOS cameras or rotating knife edges or slits, differ considerably in terms of the allowed ranges of beam radius and optical power, wavelength range, sensitivity to artifacts, etc. For example, slit or knife-edge scanners can usually handle higher powers than cameras and can be precise for nearly Gaussian-shaped beams, whereas camera-based systems are usually more appropriate for complicated beam shapes. Other issues come into play for beams with temporally varying powers, e.g. for the output of Q-switched lasers. It may then be necessary to synchronize a shutter with the laser pulses.

Instead of a moving a detector through the beam, one can use a spatial light modulator to avoid any moving parts [8].

Alternative measurement methods are based on the transmission through a mode-matched passive optical resonator or on wavefront sensors, e.g. Shack–Hartmann wavefront sensors. The full characterization of the laser beam then only requires analysis in a single plane.

Importance of Beam Quality for Applications

A high beam quality can be important e.g. when strong focusing of a beam is required. In the area of laser material processing, printing, marking, cutting and drilling often require high beam qualities, whereas welding, soldering, hardening and various other kinds of surface treatment are less critical in this respect because they work with larger spots, so that direct application of high-power laser diodes with comparatively poor beam quality (direct diode lasers) is possible. For cutting and remote welding, a relatively high beam quality (with ($M^2$) not much larger than 10) makes it possible to use a large working distance (i.e., a large distance between workpiece and focusing objective), which is highly desirable e.g. to protect the optics against debris and fumes. Also, a high beam quality reduces the beam diameters in a beam delivery system, so that smaller and thus cheaper optical elements (e.g. mirrors and lenses) can be used. Furthermore, the increased effective Rayleigh length (for a given spot size) increases the tolerance for longitudinal alignment.

A large working distance, made possible by a high beam quality, is also important for the design of diode-pumped lasers when the pump beam has to go through various pieces of optics (e.g. a dichroic mirror) before reaching the laser crystal.

A very high (close to diffraction-limited) beam quality, associated with a high spatial coherence, is often required for interferometers, optical data recording, laser microscopy, and the like.

Mode-locked lasers always must have a high beam quality, since the excitation of higher-order transverse modes would disturb the pulse formation process.

Typical Beam Quality of Certain Lasers

Generally, the beam quality is not determined by the type of laser, but there are some typical trends:

Optimizing Laser Beam Quality

Crucial factors for obtaining a high beam quality from a solid-state bulk laser are:

Beam Quality in Nonlinear Optics

Beam quality is an issue not only for lasers, but also for nonlinear frequency conversion. While thermal lensing in nonlinear crystal materials occurs only at very high average power levels (because heating occurs only through weak parasitic absorption), the beam quality can be affected by other effects:

Further, the use of a laser beam with poor beam quality in a nonlinear frequency conversion device can significantly spoil the conversion efficiency.

Beam quality effects in nonlinear optics can be investigated with numerical computer models, which can simulate the evolution of the spatial (and possibly temporal) profiles of the involved beams.

Frequently Asked Questions

What is the beam quality of a laser?

Beam quality describes how tightly a laser beam can be focused to a small spot with limited divergence, often quantified by the beam parameter product (BPP) or the ($M^2$) factor, with lower values indicating better quality.

How does the ($M^2$) factor relate to beam quality?

The ($M^2$) factor, crucial in beam quality assessment, compares the beam parameter product of a laser to that of an ideal diffraction-limited Gaussian beam, with an ($M^2$) value of 1 representing the highest beam quality.

What impacts can poor beam quality have on laser applications?

Poor beam quality often leads to increased beam divergence and less efficient focusing, which can adversely affect applications requiring precise beam targeting and high-intensity focus such as material processing and surgical procedures.

How is beam quality measured according to international standards?

Beam quality is typically measured by calculating the ($M^2$) factor according to ISO Standard 11146, which involves a fitting procedure on the beam radius at various propagation points (caustic method).

Why is high beam quality important in laser material processing?

High beam quality enables effective focusing of laser beams to smaller spots, facilitating precise and efficient cutting, drilling, and marking, whilst allowing for a greater working distance, essential for protecting optical components from debris.

Suppliers

Sponsored content: The RP Photonics Buyer's Guide contains 25 suppliers for beam quality. Among them:

Femto Easy

âš™ hardware

beam quality

Femto Easy offers various types of BeamPro beam profilers with different specifications:

They all come with a powerful and user-friendly software.

Kokyo

âš™ hardware

beam quality

Kokyo's beam profiler (developd by ourselves) supports your laser beam measurements:

Kokyo offers different packages:

The software (LaseView) also offers a free trial during 7 days.

Gentec Electro-Optics

âš™ hardware

beam quality

The BEAMAGE-M2 is an automated laser beam quality measurement system. It is the only M2 system on the market equipped with a complete set of 50-mm optics. Also, the sensor is 11.3 Ă— 11.3 mm.

Two beam-steering mirrors are included for quick and easy alignment of your laser into the system. The internal mirrors are factory-aligned and the pre-set height also simplifies the alignment.

The low-profile ingenious mechanics make it easy to fit the device on any optical table.

The calculations are fully compliant to the ISO 11146 and 13694 standards.

Make a complete, ISO-compliant measurement in only 20 seconds with the ROI feature, and in less than a minute with full-frame acquisition.

In the easy-to-navigate software, both automatic and manual settings are available, so data points can be added or removed even after an automatic scan is completed.

Bibliography

[1] ISO Standard 11146, “Lasers and laser-related equipment – Test methods for laser beam widths, divergence angles and beam propagation ratios” (2005)
[2] A. E. Siegman, “New developments in laser resonators”, Proc. SPIE 1224, 2 (1990); doi:10.1117/12.18425
[3] A. E. Siegman, “Defining, measuring, and optimizing laser beam quality”, Proc. SPIE 1868, 2 (1993); doi:10.1117/12.144597
[4] T. F. Johnston Jr., “Beam propagation (($M^2$)) measurement made as easy as it gets: the four-cuts method”, Appl. Opt. 37 (21), 4840 (1998); doi:10.1364/AO.37.004840
[5] G. Arisholm et al., “Limits to the power scalability of high-gain optical parametric oscillators and amplifiers”, J. Opt. Soc. Am.B 21 (3), 578 (2004); doi:10.1364/JOSAB.21.000578
[6] R. Paschotta, “Beam quality deterioration of lasers caused by intracavity beam distortions”, Opt. Express 14 (13), 6069 (2006); doi:10.1364/OE.14.006069
[7] E. Perevezentsev et al., “Comparison of phase-aberrated laser beam quality criteria”, Appl. Opt. 46 (5), 774 (2007); doi:10.1364/AO.46.000774
[8] C. Schulze et al., “Beam-quality measurements using a spatial light modulator”, Opt. Lett. 37 (22), 4687 (2012); doi:10.1364/OL.37.004687
[9] The Photonics Spotlight 2020-09-30: Beam radius and beam quality of laser pulses

(Suggest additional literature!)


Picture of Dr. RĂĽdiger Paschotta


Questions and Comments from Users

Here you can submit questions and comments. As far as they get accepted by the author, they will appear above this paragraph together with the author’s answer. The author will decide on acceptance based on certain criteria. Essentially, the issue must be of sufficiently broad interest.

Please do not enter personal data here. (See also our privacy declaration.) If you wish to receive personal feedback or consultancy from the author, please contact him, e.g. via e-mail.

By submitting the information, you give your consent to the potential publication of your inputs on our website according to our rules. (If you later retract your consent, we will delete those inputs.) As your inputs are first reviewed by the author, they may be published with some delay.