Cantilever Research Papers - Academia.edu (original) (raw)

The natural frequencies of skewed cantilevered thick plates are determined by using the Ritz method. The present work is the first known three-dimensional study of the problem. Assumed displacement functions are in the form of algebraic... more

The natural frequencies of skewed cantilevered thick plates are determined by using the Ritz method. The present work is the first known three-dimensional study of the problem. Assumed displacement functions are in the form of algebraic polynomials which satisfy the fixed face conditions exactly, and which are mathematically complete. Accurate natural frequencies are calculated for skewed thick plates having arbitrary degrees of skewness. Detailed numerical studies reveal interesting trends concerning the variation of frequencies with increasing skew angle. Results obtained by using the present method are compared with those obtained by using three-dimensional finite elements.

Recent measurements have indicated that the elastic behaviour of silicon nanocantilevers and nanowires is size-dependent. Several theoretical models have been proposed to explain this phenomenon, mainly focused on surface stress effects.... more

Recent measurements have indicated that the elastic behaviour of silicon nanocantilevers and nanowires is size-dependent. Several theoretical models have been proposed to explain this phenomenon, mainly focused on surface stress effects. However, discrepancies are found between experiments and theories, indicating that there could be other influences in addition to surface effects. One of the important issues, which was experimentally confirmed and has not been considered, is accounting for the fact that experimentally tested nanocantilevers and nanowires are not defect free. In this paper molecular dynamics (MD) is utilized to study the effects of defects on the elasticity of silicon. The effective Young's modulus \tilde{E} of [1 0 0] and [1 1 0] oriented silicon nanoplates is extracted in the presence of defects, showing that such defects significantly influence the size-dependent behaviour in \tilde{E} . The MD results are compared with the results of continuum theory, showing that continuum theory holds, even for very small defects. Taking into account the surface effects, native oxide layers together with fabrication-induced defects, the experimental measurements can be explained. The studied example involved nanocantilevers, but can be extended to nanowires.

The effect of temperature on structural response is a concern in engineering applications. The literature has highlighted that applied temperature loads change the system vibration behaviour. However, there is limited information... more

The effect of temperature on structural response is a concern in engineering applications. The literature has highlighted that applied temperature loads change the system vibration behaviour. However, there is limited information available about temperature impacting the dynamic response. This paper investigated the heating rates effects on modal parameters for both with crack and without crack conditions in a cantilever beam. A beam subjected to three heating rates was considered: 2, 5, and 8 °C/min. The first one was assumed as a slow heating rate while the others were assumed as moderate and high, respectively. This controlled rate of heating was achieved by using a proportional-integral-derivative (PID) temperature controller. The results showed that heating at different rates has little impact on modal parameters. While this effect is minimal at lower temperatures and more evident at higher temperatures. The results of temperature ramped at 2, 5, and 8 °C/min were compared with...

We have developed a new type of chemical microsensor based on piezoresistive microcantilever technology. In this embedded polymer microsensor, a piezoresistive microcantilever is partially “embedded” into a polymeric material. Swelling of... more

We have developed a new type of chemical microsensor based on piezoresistive microcantilever technology. In this embedded polymer microsensor, a piezoresistive microcantilever is partially “embedded” into a polymeric material. Swelling of the polymer upon analyte exposure is measured as a simple resistance change in the embedded cantilever. Arrays of these sensors, each employing a different polymeric material, provide for the

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin... more

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.

The authors report the nanomachining of sub-20-nm wide doubly clamped silicon carbon nitride resonators using low keV electron beam lithography with polymethyl methacrylate resist and cold development. Methodologies are developed for... more

The authors report the nanomachining of sub-20-nm wide doubly clamped silicon carbon nitride resonators using low keV electron beam lithography with polymethyl methacrylate resist and cold development. Methodologies are developed for precisely controlling the resonator widths in the ultranarrow regime of 11–20 nm. Resonators with lengths of 1–20 μm and widths of 16–280 nm are characterized at room temperature in vacuum using piezoelectric actuation and optical interferometry. Clamping and surface losses are identified as the dominant energy loss mechanisms for a range of resonator widths. The resonator clamping points are optimized using an original electron beam lithography simulator. Various alternative clamping point designs are also modeled and fabricated in order to reduce the clamping losses.